2-Clinic Feasibility Study: Inverse Scatter Breast Scan

Information

  • Research Project
  • 7477996
  • ApplicationId
    7477996
  • Core Project Number
    R44CA110203
  • Full Project Number
    5R44CA110203-03
  • Serial Number
    110203
  • FOA Number
    PA-04-94
  • Sub Project Id
  • Project Start Date
    9/13/2006 - 18 years ago
  • Project End Date
    6/30/2010 - 14 years ago
  • Program Officer Name
    BEYLIN, DAVID M
  • Budget Start Date
    7/1/2008 - 16 years ago
  • Budget End Date
    6/30/2010 - 14 years ago
  • Fiscal Year
    2008
  • Support Year
    3
  • Suffix
  • Award Notice Date
    8/12/2008 - 16 years ago
Organizations

2-Clinic Feasibility Study: Inverse Scatter Breast Scan

[unreadable] DESCRIPTION (provided by applicant): This Phase-l SBIR project, of a Fast Track pair, will provide concept testing, computer simulation studies, laboratory-based hardware emulation and a final specification for the final scanner to be constructed in the Phase ll SBIR project. The result of this Fast Track effort is intended to be used as the foundation, starting specifications and design for the construction and clinical testing of a pair of advanced, second-generation, "Ultrasound CT(tm)" breast cancer detection and diagnostic scanners. No construction of scanner components will be done during Phase-l. During Phase-ll, these two second generation scanners would be installed at Mayo Clinic and at the University of California at San Diego Hospital. These second generation scanners include improved features over TechniScan's first generation scanner that was installed in a local cancer center in August 2004. The first generation scanners consist of two opposing, but parallel, 2-D transducer arrays that rotate about a pendent breast in a water tank. The arrays also are moved vertically after each 360 degree rotation. Inverse Scattering, 3-D, Tomographic images were computed for sound speed and acoustic attenuation. Since August 2004 new transmit and receiver arrays are being incorporated. To these capabilities the second generation scanner adds: (1) improved inverse scattering in-plane spatial resolution and signal to noise ratio by beam shading and by relative rotation between transmit and receiver arrays; (2) improved inverse scattering spatial resolution by tilting the arrays in a vertical direction; and (3) improved reflectivity imaging by adding a commercial OEM beam former. [unreadable] [unreadable]

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R44
  • Administering IC
    CA
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    925339
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
    NCI:925339\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    TECHNISCAN, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84106
  • Organization District
    UNITED STATES