3-D Ultrasound vascular Blood Flow Imaging

Information

  • Research Project
  • 6643437
  • ApplicationId
    6643437
  • Core Project Number
    R44HL065771
  • Full Project Number
    5R44HL065771-03
  • Serial Number
    65771
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/18/2000 - 24 years ago
  • Project End Date
    7/31/2004 - 20 years ago
  • Program Officer Name
    BUXTON, DENIS B.
  • Budget Start Date
    8/1/2003 - 21 years ago
  • Budget End Date
    7/31/2004 - 20 years ago
  • Fiscal Year
    2003
  • Support Year
    3
  • Suffix
  • Award Notice Date
    8/7/2003 - 21 years ago
Organizations

3-D Ultrasound vascular Blood Flow Imaging

DESCRIPTION (provided by applicant): During Phase I, VueSonix Sensors demonstrated for the first time ever, true real-time, digital phased array, 3-0 Ultrasound Color Flow and Power Doppler imaging of blood flow. This could be called a 5-D vascular imaging system (x y z v t), operating at 30 FPS. In addition, the threedimensional blood vessel centerline was instantaneously acquired, tracked and displayed as needed for true 3-D vector velocity and for non-invasive measurement and monitoring of blood volume flow. The 3D image can be fully rotated andlor viewed as a fixed or moving slice in any axis. The Phase I Engineering Model used a small transducer array, with a limited angular field of view, to produce 200,000 voxels/sec with a fantastic 4x improvement in velocity (color) resolution over 2D systems. In Phase II, VueSonix will fully reduce its invention (patent pending, submitted 6/99 81 7/99) to practice by building and testing a prototype system with a full-size probe producing images with 12 times the number of voxels as the engineering model. The prototype will be optimized for the peripheral vascular market and will be clinically tested at Thomas Jefferson University Hospital. Cardiac imaging will also be evaluated. PROPOSED COMMERCIAL APPLICATIONS: Vuesonix is developing commercial ultrasound devices that image blood vessels in real time 3D. The objective is to provide superior blood flow imaging with volume blood-flow measurements resulting in improved diagnosis requiring less operator skill. A market survey performed for VueSonix by Health Advances, Inc., shows a $350M-550M market in the U.S. for a device to diagnose and monitor periphral vascular disease that requires less tiem and less operator skill.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    347750
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:347750\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    VUESONIX SENSORS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    MOORESTOWN
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    08057
  • Organization District
    UNITED STATES