Information
-
Trademark
-
99035851
-
International Classifications
-
Filing Date
February 10, 2025
a year ago
-
Transaction Date
July 25, 2025
9 months ago
-
Status Date
July 24, 2025
10 months ago
-
Location Date
July 24, 2025
10 months ago
-
First Use Anywhere Date
June 26, 2023
2 years ago
-
First Use In Commerce Date
June 26, 2023
2 years ago
-
Status Code
641
-
Current Location
TMO LAW OFFICE 114
Employee Name
BROOKSHIRE,DAVID AARON
-
Attorney Docket Number
FASI-T015US
Attorney Name
Frank P Grassler
Law Office Assigned Location Code
M50
-
Owners
Case File Statements
- DM0000: The mark consists of The mark consists of a set of fanciful curvilinear shapes in white that together are suggestive of a helical-like structure. The mark may appear on any contrasting background color.
- CC0000: The color(s) white is/are claimed as a feature of the mark.
- GS0101: Medical devices, namely, pulse generators for the field of neurology to generate closed loop neuroelectric stimulation impulses complementary to real-time measured afferent electrical impulses through the skin to therapeutically modulate a dysfunctional brain cerebello-thalamo-cortical circuit for tremor reduction; stand-alone wearable devices for use in neurology in treating tremors non-surgically; stand-alone wearable devices for operating in a closed loop measurement and generation circuit enabling generation of neurologically-effective electrical energy to the brain; stand-alone therapeutic devices worn throughout the day in a closed loop measurement and generation circuit enabling generation of neurologically-effective electrical impulses to the brain without online communication connectivity and without downloads of data from any outside source; stand-alone therapeutic devices worn on the wrist throughout the day in a closed loop measurement and generation circuit enabling generation of neurologically-effective electrical impulses to the brain without online communication connectivity and without downloads of image data from any outside source; wearable stand-alone accelerometers that, in a closed loop circuit, measure physical acceleration to generate complementary neuroelectric stimulation impulses through the skin to therapeutically modulate a dysfunctional brain in the treatment of tremors.
Case File Event Statements
-
2/10/2025 - a year ago
1 - NEW APPLICATION ENTERED
Type: NWAP
-
2/10/2025 - a year ago
2 - APPLICATION FILING RECEIPT MAILED
Type: MAFR
-
7/13/2025 - 10 months ago
3 - NEW APPLICATION OFFICE SUPPLIED DATA ENTERED
Type: NWOS
-
7/18/2025 - 10 months ago
5 - ASSIGNED TO EXAMINER
Type: DOCK
-
7/24/2025 - 10 months ago
7 - NON-FINAL ACTION E-MAILED
Type: GNRT
-
7/24/2025 - 10 months ago
6 - NON-FINAL ACTION WRITTEN
Type: CNRT
-
7/24/2025 - 10 months ago
8 - NOTIFICATION OF NON-FINAL ACTION E-MAILED
Type: GNRN
-
7/13/2025 - 10 months ago
4 - NOTICE OF DESIGN SEARCH CODE E-MAILED
Type: MDSC