A microfluidic chemotaxis device for high content screening

Information

  • Research Project
  • 7921018
  • ApplicationId
    7921018
  • Core Project Number
    R44HL088785
  • Full Project Number
    5R44HL088785-03
  • Serial Number
    88785
  • FOA Number
    PA-08-050
  • Sub Project Id
  • Project Start Date
    9/1/2009 - 17 years ago
  • Project End Date
    12/31/2011 - 14 years ago
  • Program Officer Name
    APPLEBAUM-BOWDEN, DEBORAH
  • Budget Start Date
    7/1/2010 - 16 years ago
  • Budget End Date
    12/31/2011 - 14 years ago
  • Fiscal Year
    2010
  • Support Year
    3
  • Suffix
  • Award Notice Date
    7/8/2010 - 16 years ago
Organizations

A microfluidic chemotaxis device for high content screening

DESCRIPTION (provided by applicant): Leukocyte recruitment is central to inflammation, and there is intense focus on inhibiting the process both for chronic inflammatory disorders and for conditions where inflammation plays a contributory role, such as atherosclerosis. Whereas current anti-inflammatory drugs such as NSAIDs target secondary effects that are induced after inflammation is already established, inhibiting leukocyte recruitment would prevent the initiation of inappropriate inflammatory responses. Chemotaxis - the movement of cells aligned with a chemical gradient - is the fundamental process underlying neutrophil recruitment. Despite its importance, there are limited screening tools available for medium to high throughput analysis of leukocyte recruitment. Typically, primary screening incorporates a molecular target such as an enzyme or receptor, and hits are then validated in cumbersome in vitro cell migration assays. Existing assays suffer from three main problems: 1) Lack of repeatability (e.g. due to trapped air), 2) need for manual operations (e.g. filter removal), and 3) large cell number requirement (e.g. 1x105 cells/datum). We aim to solve each of these problems by taking advantage of microfluidic technology. In this phase II project we will establish injection molding of full plate (i.e. 96 unit) parts and adapt manufacturing methods developed under the phase I grant to produce devices that suitable for automation. We will use these devices to show reproducibility and data quality while reducing the number of cells required per datum 10-fold. Importantly we will demonstrate the use of the microfluidic chemotaxis device in a high content screening study where multi-parametric image- based analysis is applied to test both migration and polarization of primary human neutrophils. PUBLIC HEALTH RELEVANCE: The migration of cells from the bloodstream to sites of injury is one of the fundamental processes underlying chronic inflammatory disorders such as arthritis and inflammatory bowel disease. Responding cells migrate toward higher concentrations of signaling molecules that are released at the injury site. To enable the discovery of drugs to block this process, we are developing plastic devices for high throughput cell migration assays in defined chemical gradients.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    431441
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:431441\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    BELLBROOK LABS, LLC
  • Organization Department
  • Organization DUNS
    119165251
  • Organization City
    MADISON
  • Organization State
    WI
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    537114951
  • Organization District
    UNITED STATES