A MINIMALLY INVASIVE MOTILITY VISUALIZING SYSTEM

Information

  • Research Project
  • 6015278
  • ApplicationId
    6015278
  • Core Project Number
    R43DK056539
  • Full Project Number
    1R43DK056539-01
  • Serial Number
    56539
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/30/1999 - 26 years ago
  • Project End Date
    3/29/2000 - 25 years ago
  • Program Officer Name
    PODSKALNY, JUDITH M.
  • Budget Start Date
    9/30/1999 - 26 years ago
  • Budget End Date
    3/29/2000 - 25 years ago
  • Fiscal Year
    1999
  • Support Year
    1
  • Suffix
  • Award Notice Date
    9/8/1999 - 26 years ago

A MINIMALLY INVASIVE MOTILITY VISUALIZING SYSTEM

The development of a Motility Visualization System (MVS) is proposed for detecting and diagnosing problems associated with the muscular function of the gastrointestinal track. The system includes a high spatial density, pressure distribution sensing catheter capable of measuring the peristaltic waves of contraction as they propagate and an intuitive visualization software package that display this spatial-temporal data in real time. Phase I involves the design, construction, and evaluation of an innovative sold-stage catheter that uses a proprietary pressure sensing technology of Pressure Profile Systems, Inc. This sensing technique has been developed for other biomechanical measurement applications with similar requirements. This catheter represents a significant advancement over current designs by dramatically increasing the number of sampling elements and allowing integration into an easy-to-use data collection system. MVS has the power to revolutionize motility sensing procedures by simplifying the data collection process while producing high quality measurements useful for advanced diagnosis. This has the immediate clinical benefit of improving esophageal manometry and allows application of these techniques to other parts of the gastrointestinal tract. PROPOSED COMMERCIAL APPLICATIONS: The research and development plan outlined in this proposal develops the next generation of Motility Visualization System (MVS) that provide user-friendly, high resolution graphical display for clinical motility assessment.

IC Name
NATIONAL INSTITUTE OF DIABETES AND DIGESTIVE AND KIDNEY DISEASES
  • Activity
    R43
  • Administering IC
    DK
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    847
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
  • Organization Name
    PRESSURE PROFILE SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    LOS ANGELES
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    900456401
  • Organization District
    UNITED STATES