A System for Rapid PCR, Mutation Scanning and Genotyping

Information

  • Research Project
  • 6882751
  • ApplicationId
    6882751
  • Core Project Number
    R42GM073396
  • Full Project Number
    1R42GM073396-01
  • Serial Number
    73396
  • FOA Number
  • Sub Project Id
  • Project Start Date
    3/1/2005 - 19 years ago
  • Project End Date
    8/31/2005 - 19 years ago
  • Program Officer Name
    SWAIN, AMY L
  • Budget Start Date
    3/1/2005 - 19 years ago
  • Budget End Date
    8/31/2005 - 19 years ago
  • Fiscal Year
    2005
  • Support Year
    1
  • Suffix
  • Award Notice Date
    2/28/2005 - 19 years ago
Organizations

A System for Rapid PCR, Mutation Scanning and Genotyping

[unreadable] DESCRIPTION (provided by applicant): Our objective is to provide a closed-tube system for rapid PCR, mutation scanning and genotyping that does not require fluorescently-labeled probes. For many genetic diseases, it is difficult and expensive to screen for all possible mutations that may cause the disease. We propose a relatively simple solution for rapid amplification, scanning and genotyping in a single homogeneous system. Certain DNA dyes are compatible with PCR and can detect mismatches between two copies of DNA by simple melting analysis after amplification. The dye is added before PCR, and heterozygotes are easily identified after a 1-2 min high-resolution melting curve after PCR. Specific genotype confirmation is provided by an unlabeled oligonucleotide probe. The specific aims for Phase I of this Fast Track proposal are: 1. Develop a homogeneous, closed-tube gentotyping method that uses unlabeled oligonucleotides. 2. Prototype a rapid PCR system that integrates high-resolution melting analysis for scanning and genotyping. We will integrate the high-resolution melting capability of our HR-1 instrument into our rapid PCR machine (R.A.P.I.D./LightCycler). After PCR, each tube will be automatically analyzed by high-resolution melting. Simultaneous scanning and genotyping will be demonstrated using special DNA dyes. Advantages of our system includes speed (PCR in 15 min, analysis in 1-2 min/sample), homogeneous design (no need for sample transfer or reagent additions), closed-tube analysis (no amplicon contamination risk), both scanning and genotyping capability, and nondestructive analysis (immediately available for sequencing in the rare case when it is necessary). [unreadable] [unreadable]

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R42
  • Administering IC
    GM
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    100000
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    859
  • Ed Inst. Type
  • Funding ICs
    NIGMS:100000\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    IDAHO TECHNOLOGY
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84108
  • Organization District
    UNITED STATES