A Wearable Balance Booster - Stepping Closer to the Market

Information

  • Research Project
  • 8517335
  • ApplicationId
    8517335
  • Core Project Number
    R44AG040865
  • Full Project Number
    2R44AG040865-02
  • Serial Number
    040865
  • FOA Number
    PA-12-088
  • Sub Project Id
  • Project Start Date
    9/15/2011 - 13 years ago
  • Project End Date
    5/31/2015 - 9 years ago
  • Program Officer Name
    JOSEPH, LYNDON
  • Budget Start Date
    6/1/2013 - 11 years ago
  • Budget End Date
    5/31/2014 - 10 years ago
  • Fiscal Year
    2013
  • Support Year
    02
  • Suffix
  • Award Notice Date
    5/31/2013 - 11 years ago
Organizations

A Wearable Balance Booster - Stepping Closer to the Market

DESCRIPTION (provided by applicant): The overall goal of this project is to continue development and commercialization of a Balance Sensory Augmentation and Substitution System (B-SASS). The device termed Walkasins measures foot pressure through a thin sole insert, developed under recent Phase I funding, and displays pressure information through a vibrotactile feedback array, placed around the lower leg, to help improve balance function. The device can either substitute lost foot pressure sensation; e.g. in individuals with peripheral neuropathy or it can act as a balance booster providing an augmentation of sensory information to individuals with general balance problems. The device can be worn in bed at night and turns on automatically when the wearer gets out of bed to go, e.g. to the bathroom. We have acquired pilot data demonstrating that clinical parameters reflecting gait balance and mobility improve when elderly at-risk fallers use the device bringing them to non- faller status. For the current Phase II proposal our specific aims are to: 1. Revise and finalize design of Walkasins based on accomplishments, user input, as well as reviewer criticism from our Phase 1 grant and manufacture 200 units of the device for clinical testing. Milestone 1: 200 units manufactured and ready for clinical testing under Aim 2 2. In a double-blind randomized control trial investigate effects of using Walkasins on clinical outcomes related to gait, balance functio and associated fall risk in a hospital-based outpatient rehabilitation program at the Sister Kenny Rehabilitation Institute in Minneapolis. Hypotheses 1A-C: Patients who participate in a comprehensive outpatient rehabilitation program and use Walkasins programmed to display relevant balance cues will attain higher gait speed, Functional Gait Assessment and Balance Confidence following their episode of care when compared to a matched cohort using Walkasins programmed to vibrate similarly although unrelated to balance. Hypothesis 2: Patients who use Walkasins on a daily basis during their episode of care will not experience issues related to skin irritation. Milestone 2: Data confirming the clinical utility and long-term se safety of the Walkasins on patients' participating in a hospital-based comprehensive outpatient rehabilitation program.

IC Name
NATIONAL INSTITUTE ON AGING
  • Activity
    R44
  • Administering IC
    AG
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    618129
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    866
  • Ed Inst. Type
  • Funding ICs
    NIA:618129\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    MRS
  • Study Section Name
    Musculoskeletal Rehabilitation Sciences Study Section
  • Organization Name
    RXFUNCTION, INC.
  • Organization Department
  • Organization DUNS
    963353821
  • Organization City
    EDINA
  • Organization State
    MN
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    554241047
  • Organization District
    UNITED STATES