A wearable functional-brain-imaging system with full-head coverage and enhanced spatiotemporal-resolution to study complex neural circuits in human subjects

Information

  • Research Project
  • 10020974
  • ApplicationId
    10020974
  • Core Project Number
    U01EB028656
  • Full Project Number
    5U01EB028656-02
  • Serial Number
    028656
  • FOA Number
    RFA-EB-17-004
  • Sub Project Id
  • Project Start Date
    9/21/2019 - 5 years ago
  • Project End Date
    5/31/2024 - 7 months ago
  • Program Officer Name
    WANG, SHUMIN
  • Budget Start Date
    6/1/2020 - 4 years ago
  • Budget End Date
    5/31/2021 - 3 years ago
  • Fiscal Year
    2020
  • Support Year
    02
  • Suffix
  • Award Notice Date
    6/24/2020 - 4 years ago

A wearable functional-brain-imaging system with full-head coverage and enhanced spatiotemporal-resolution to study complex neural circuits in human subjects

PROJECT SUMMARY/ABSTRACT To develop maps at multiple scales of neuronal circuits in the human brain and study the brain dynamics, there is a need for non-invasive functional brain imaging with high spatiotemporal resolution operating in natural environments. Among non-invasive functional brain imaging methods, magnetoencephalography (MEG) is the only technology that can map cortical activity down to millimeter spatial resolution with millisecond time resolution. Current cryogenic MEG systems employ superconducting quantum interference device (SQUID) magnetometers. The cryogenic operation requires sensor arrays that are rigid and fixed in a helmet, and the helmet size is optimized to fit the largest adult heads. The rigid helmet limits source-to-sensor distances to >3 cm which compromises the maximum achievable signal-to-noise ratio (SNR) and hence spatial resolution. Furthermore, due to their design, these SQUID-based MEG systems are costly and impractical for experiments in natural environments. Recent simulation studies have shown that on-scalp MEG can maximize SNR and achieve spatial resolution approaching 1 mm. Optically pumped magnetometers (OPMs) are a valid candidate for MEG sensors, as they operate above room temperature, and the sensor layout can be conformal to the scalp. The overall objective of this project is to develop a wearable, conformable, full-head coverage, 108- channel, OPM-based MEG system with unprecedented spatial resolution approaching 1 mm. The first Aim will develop the whole-cortex 108-channel OPM array along with the supporting systems (optical, electronic, software, etc.). The OPM MEG will be installed in a magnetically shielded room so that the array can be worn and move with the subject, enabling more naturalistic study paradigms. The second Aim will leverage the high- frequency spatial features available to the on-scalp OPMs to enhance the spatial resolution of the MEG system. Given unique subjects' head shapes, adaptive sampling of the magnetic topography (image) is essential to maximize the captured spatial frequency. Hence, information-theoretic analysis will be used to maximize the spatial resolution by optimizing the sensors locations. With the array being reconfigurable, rapid calibration techniques will be developed to determine the position of each OPM for each subject. To eliminate external magnetic noise and compensate for movement-induced distortion, physics-based models will be employed. The final Aim cross validates the performance metrics of the new OPM MEG system with a commercial SQUID system. By measuring retinotopy in the visual cortex, spatial localization between the MEG systems will be compared. By stimulating cerebellar activity, it will be studied if the conformal OPM array can better capture activity in this difficult-to-study region of the brain. Finally, by measuring resting-state MEG, intrinsic network connectivity in the human brain will be captured. This project will provide a whole-head OPM array that improves MEG measurements for people of all head sizes (from premature infants to the largest adults) and enable new experimental paradigms with a wearable array operating in semi-natural settings.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    U01
  • Administering IC
    EB
  • Application Type
    5
  • Direct Cost Amount
    873145
  • Indirect Cost Amount
    558752
  • Total Cost
    1431897
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:715897\NINDS:716000\
  • Funding Mechanism
    Non-SBIR/STTR RPGs
  • Study Section
    ZEB1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    SANDIA CORP-SANDIA NATIONAL LABORATORIES
  • Organization Department
  • Organization DUNS
    007113228
  • Organization City
    ALBUQUERQUE
  • Organization State
    NM
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    871233453
  • Organization District
    UNITED STATES