Adaptation of an Adult Endotracheal Tube Monitoring System for Use in Neonatal In

Information

  • Research Project
  • 8064344
  • ApplicationId
    8064344
  • Core Project Number
    R43HL106367
  • Full Project Number
    5R43HL106367-02
  • Serial Number
    106367
  • FOA Number
    RFA-HD-09-017
  • Sub Project Id
  • Project Start Date
    5/1/2010 - 14 years ago
  • Project End Date
    1/31/2014 - 10 years ago
  • Program Officer Name
    BLAISDELL, CAROL J
  • Budget Start Date
    5/1/2011 - 13 years ago
  • Budget End Date
    1/31/2014 - 10 years ago
  • Fiscal Year
    2011
  • Support Year
    2
  • Suffix
  • Award Notice Date
    4/19/2011 - 13 years ago
Organizations

Adaptation of an Adult Endotracheal Tube Monitoring System for Use in Neonatal In

DESCRIPTION (provided by applicant): Endotracheal tube (ETT) intubation in neonates is associated with numerous complications which create immediate costs in excess of $250M annually in the U.S., as well as post-incidence costs that can be considerable, and immeasurable emotional costs to parents and clinicians. Compared to adults, this patient group is especially fragile where a slight movement of the ETT into an improper location can lead to rapid deterioration of their condition sometimes resulting in catastrophic consequences. SonarMed has developed a novel device using a sonar-based technique to provide precise, real-time adjunctive information regarding endotracheal tube position and function in the adult intensive care unit. While this technology, called the SonarMed" Airway Monitoring System (AMS), will provide benefits in the adult ICU, the greatest impact from its use is expected to be experienced in the neonate, where it will offer clinicians the ability to noninvasively and continuously monitor tube placement without the use of x-rays. The long-term objective of this proposed project is to develop an AMS appropriate for use in neonates. To accomplish this, the first step will be to determine the feasibility of adapting the AMS for use in the NICU. This Phase I project will focus on first determining the unique NICU user requirements through surveys with NICU personnel, adapting the adult AMS for NICU-size ETTs, and collecting acoustic reflection data in both animals and humans. The acoustic reflection data will then be used to investigate signal optimization techniques and develop a prototype ETT position tracking algorithm. Following Phase I, the AMS will be re-engineered based on the requirements established by the end-users, evaluated in clinical studies to show safety and efficacy, and finally submitted to the FDA for market clearance. With over 43,000 NICU intubations per year in the U.S., the market for this product is expected to be in excess of $18MM per year. PUBLIC HEALTH RELEVANCE: There are currently a number of challenges with using breathing tubes in premature infants. The consequences of these challenges are significant in terms of both health outcomes for the infant as well as costs to the U.S. healthcare system. This research will provide caregivers with a new monitoring tool intended to reduce the frequency and severity of complications associated with breathing tube use in premature infants.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    224593
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:224593\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZHD1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    SONARMED, INC.
  • Organization Department
  • Organization DUNS
    198245628
  • Organization City
    Indianapolis
  • Organization State
    IN
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    462684184
  • Organization District
    UNITED STATES