Additive Manufacturing of Patient-Specific Masks and Nasal Prongs to Improve Pediatric Ventilation Outcomes and Reduce Pressure Sores

Information

  • Research Project
  • 10258024
  • ApplicationId
    10258024
  • Core Project Number
    R44HD105552
  • Full Project Number
    1R44HD105552-01
  • Serial Number
    105552
  • FOA Number
    PA-20-262
  • Sub Project Id
  • Project Start Date
    5/1/2021 - 3 years ago
  • Project End Date
    4/30/2022 - 2 years ago
  • Program Officer Name
    OCTOBER, TESSIE
  • Budget Start Date
    5/1/2021 - 3 years ago
  • Budget End Date
    4/30/2022 - 2 years ago
  • Fiscal Year
    2021
  • Support Year
    01
  • Suffix
  • Award Notice Date
    4/28/2021 - 3 years ago
Organizations

Additive Manufacturing of Patient-Specific Masks and Nasal Prongs to Improve Pediatric Ventilation Outcomes and Reduce Pressure Sores

In this Fast-track SBIR Actuated Medical, Inc., is partnering with the Children?s Hospital of Philadelphia (CHOP) and Akron Children?s Hospital (ACH) to develop processes to manufacture better fitting masks and nasal prongs for Non-invasive Ventilation (NIV) delivery to young pediatric patients (1 month to 9 years of age). NIV provides breathing support without the use of an endotracheal or tracheostomy tube. NIV is delivered by interfaces (a mask or nasal prongs). Generally, masks only cover the nose to mitigate potential aspiration concerns should a patient vomit. Nasal prongs are intended to achieve a 100% occlusive fit within a patient?s nare. For both masks and prongs, the goal is to deliver airway support maintaining positive-end expiratory pressure (PEEP). Poorly fitting masks can lead to non-compliance, patient?ventilator dys?synchronies, skin damage, pain, craniofacial skeletal issues, and can also result in delivery of sub-optimal pressures or tidal volume, which can adversely affect ventilation outcomes, particularly in the home care setting. Additionally, poorly fitting NIV interfaces can require them to be strapped to patients tightly to offset the inferior fit, which can lead to pressure ulcers, skin damage, or septum injury (in the case of nasal prongs). While many NIV delivery methods exist for neonatal patients (3 available mask and 11 nasal prong sizes), there are no sizes designed specific to young pediatric patients (1 month to 9 years old) that are equipped with appropriate headgear. The validation process to stand up a manufacturing approach is costly and time consuming for a relatively small market, limiting the interest of major manufacturers to fill these gaps. Three main limitations arise when addressing the needs of younger patients: 1) the size gap between neonatal and adult interfaces leave poor solutions for young pediatric patients, 2) variation in patient facial structure results in NIV interfaces being pushed too firmly against the face in an attempt to eliminate or reduce air leakage, and 3) craniofacial anomalies (CFAs) (e.g. cleft lip) further limit the ability to achieve a good seal. An approach is needed that will produce NIV interfaces that address these gaps, while being FDA-compliant and still economically feasible. Phase I. Hypothesis. Pediatric-specific sized NIV mask and prongs can be manufactured using 3D printing methods to improve ventilation outcomes in benchtop models. Aim 1. Verify improved performance of pediatric-sized NIV devices fabricated through facial scanning and injection molding process. Aim 2 ? Formulation development and testing for direct 3D printing approach. Phase II. Hypothesis. Manufacturing NIV devices with 3D printing yields better fitting interfaces that improve NIV outcomes in young pediatrics. Aim 3 ? Validate manufacturing approach for pediatric NIV interfaces. Aim 4 ? Finalize direct 3D print approach and evaluate performance with CFAs. Aim 5 ? Multi-site human clinical evaluations (CHOP, n=29; ACH, n=24)

IC Name
EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH & HUMAN DEVELOPMENT
  • Activity
    R44
  • Administering IC
    HD
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    309518
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    865
  • Ed Inst. Type
  • Funding ICs
    NICHD:309518\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ACTUATED MEDICAL, INC.
  • Organization Department
  • Organization DUNS
    791379030
  • Organization City
    BELLEFONTE
  • Organization State
    PA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    168238445
  • Organization District
    UNITED STATES