Advanced Energy Storage Film Capacitors for Automated External Defibrillators

DESCRIPTION (provided by applicant): More than 1000 American die every single day due to sudden cardiac arrest (SCA), which claims more lives than breast cancer, AIDS, and lung cancer combined. The survival from SCA strongly depends on the early defibrillation and the probability of survival decreases by 7-10% for every minute of delay in defibrillation. In fact, less than 5% of patients with out-of-hospital SCA can survive to hospitalization. It has been found that automated external defibrillators (AED) can at least double the overall survival rate for out-of-hospital cardiac arrest patients. In this fast-track SBIR program, Strategic Polymer Sciences, Inc. (SPS) proposes to develop low-cost compact film capacitors with ultra-high electrical energy density for portable AED. The advanced capacitors will utilize the recent breakthrough dielectric materials discovered at Penn State University (Zhang et al. Science 280:2101;313:334;321:821;&Nature 419:284) and the commercial-scale resin production and thin film processing technologies developed by SPS. For the same amount of delivered energy, the SPS capacitors will be 80% smaller and 50% cheaper than the current polypropylene (PP) AED capacitors. The advanced SPS film capacitors will shrink the size and reduce the cost of AED, facilitate the deployment of AED in millions of American homes and public buildings, and save thousands of patients with heart arrhythmia problem. PUBLIC HEALTH RELEVANCE: The development of ultra-high energy density capacitors based on advanced SPS dielectric materials can significantly reduce the size and cost of Automated External Defibrillators (AED). This will enable the deployment of AED in millions of homes of patients with heart arrhythmia problem who are facing the threat of delayed defibrillation if AED not available.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    4
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    374904
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:374904\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    STRATEGIC POLYMER SCIENCES, INC.
  • Organization Department
  • Organization DUNS
    784136116
  • Organization City
    STATE COLLEGE
  • Organization State
    PA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    168036602
  • Organization District
    UNITED STATES