AUTO-ANALYZER FOR FIVE HEMOGLOBIN SPECIES AND BILIRUBIN

Information

  • Research Project
  • 3508771
  • ApplicationId
    3508771
  • Core Project Number
    R44HL044802
  • Full Project Number
    2R44HL044802-02
  • Serial Number
    44802
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/1/1991 - 33 years ago
  • Project End Date
    8/31/1993 - 31 years ago
  • Program Officer Name
  • Budget Start Date
    9/1/1991 - 33 years ago
  • Budget End Date
    8/31/1992 - 32 years ago
  • Fiscal Year
    1991
  • Support Year
    2
  • Suffix
  • Award Notice Date
    8/22/1991 - 33 years ago
Organizations

AUTO-ANALYZER FOR FIVE HEMOGLOBIN SPECIES AND BILIRUBIN

DESCRIPTION (Investigator's Abstract): The overall goal of Dr. Steinke's Phase II is to develop a spectrophotometric instrument capable of measuring eight quantities directly in a sample of undiluted whole blood. These include: THb (total hemoglobin concentration); percent Hb02 (percent oxyhemoglobin saturation); percent HbCO (percent carboxyhemoglobin saturation); percent Hi (percent methemoglobin saturation; also known as hemiglobin); percent Hb (percent deoxyhemoglobin saturation); percent SHb (percent sulfhemoglobin saturation); [02] (Hb02 concentration, which approximates oxygen content); and [Bill} (bilirubin concentration). In Phase I, Dr. Steinke developed a prototype spectrophotometer, based on a computer-controlled miniature monochromator, which made measurements in whole blood in spite of blood's well known light scattering properties. To measure the five hemoglobin species and bilirubin requires 6 carefully chosen measuring wavelengths and a 7th wavelength to correct for light scattering; THb and [02] are computed variables not requiring specific wavelengths. The principal aim of Phase II is to evaluate four sources of the 7 monochromatic wavelengths needed for the measurements. The purpose of doing so is to increase the ruggedness of the final design, prove the stability and wavelength stability, and achieve a significant reduction in manufacturing costs. He will fabricate and test four different light sources: (1) Fixed-diffraction grating - multiple light source array. In this light source, individual beams will be focused through seven adjacent input slits onto a single grating. Light enters only one slit at a time because only one lamp at a time will be illuminated. The entrance slits are carefully machined sot that they select each of the 7 desired wavelengths. (2) Hybrid circuit LED array and filter wheel. This light source will consist of an array of seven light emitting diodes(LED's), one for each of the required analytical wavelengths. The emission of each LED will pass through a narrow-band interference filter mounted on a filter wheel. During each measurement cycle, the desired wavelengths will be selected sequentially by rotating the appropriate filter into position in front of the sample and simultaneously energizing the corresponding LED. (3) Special cam monochromator. This light source will consist of a miniature monochromator with a special cam shaft. The special cam will be used to rotate a diffraction grafting, and will have one distinct radius for each of the seven analytical wavelengths. (4) Samarium-neon hollow cathode lamp. Samarium and neon together provide emission wavelengths very close to each of the seven optimal wavelengths to be utilized in Dr. Steinke's device. Light from this source will be sequentially passed through seven filters, each of which will eliminate all wavelengths except the one assigned to that filter.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    839
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    HEM
  • Study Section Name
    Hematology Subcommittee 2
  • Organization Name
    AVOX SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    FAIR OAKS RANCH
  • Organization State
    TX
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    780154809
  • Organization District
    UNITED STATES