BIOSENSOR FOR RAPID DETECTION OF HUMAN PATHOGENS

Information

  • Research Project
  • 2717730
  • ApplicationId
    2717730
  • Core Project Number
    R41GM056032
  • Full Project Number
    3R41GM056032-01S1
  • Serial Number
    56032
  • FOA Number
  • Sub Project Id
  • Project Start Date
    7/15/1997 - 27 years ago
  • Project End Date
    7/14/1998 - 26 years ago
  • Program Officer Name
  • Budget Start Date
    7/15/1997 - 27 years ago
  • Budget End Date
    7/14/1998 - 26 years ago
  • Fiscal Year
    1998
  • Support Year
    1
  • Suffix
    S1
  • Award Notice Date
    1/30/1998 - 26 years ago
Organizations

BIOSENSOR FOR RAPID DETECTION OF HUMAN PATHOGENS

The aim of this proposal is to establish the feasibility of a biosensor for detecting nucleic acid hybridization to be used in conjunction with polymerase chain reaction (PCR) of target nucleic acid base sequences from clinical samples suspected of containing pathogenic organisms or viruses. The biosensor has potentially many advantages over current methods of hybridization, including lack of chemical or radioactive labels, quantitation of product, and rapid hybridization reactions. A disposable sensing element now appear feasible. Phase I goals are to: (a) design and construct an automated hybridization cell for the biosensor; (b) write and test software for control of sensor cell and data collection; (c ) prepare more consistent biosensor surfaces using pulsed plasma polymerization; (d) increase signal to noise ratio by decreasing nonspecific binding; (e) develop a capillary, nested PCR procedure for the Shiga-like toxin genes in E. coli 0157:H7; and (f) evaluate the automated biosensor's potential to provide sensitive and very rapid pathogen detection using E. coli 0157:H7 as an example. The Phase II objectives are to construct a commercial prototype instrument that can accommodate multiple sensors, to explore larger scale production of sensing elements, to target human pathogens where the need for improved tests are greatest, and to begin biosensor evaluation with a medical diagnostic laboratory partner.

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R41
  • Administering IC
    GM
  • Application Type
    3
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    821
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG5
  • Study Section Name
  • Organization Name
    O.I. ANALYTICAL
  • Organization Department
  • Organization DUNS
  • Organization City
    COLLEGE STATION
  • Organization State
    TX
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    77845
  • Organization District
    UNITED STATES