Breathing Tube Position and Patency Monitoring System

Information

  • Research Project
  • 7500266
  • ApplicationId
    7500266
  • Core Project Number
    R44HL080796
  • Full Project Number
    5R44HL080796-05
  • Serial Number
    80796
  • FOA Number
    PA-06-20
  • Sub Project Id
  • Project Start Date
    6/1/2005 - 18 years ago
  • Project End Date
    6/30/2010 - 13 years ago
  • Program Officer Name
    HARABIN, ANDREA L.
  • Budget Start Date
    7/1/2008 - 15 years ago
  • Budget End Date
    6/30/2010 - 13 years ago
  • Fiscal Year
    2008
  • Support Year
    5
  • Suffix
  • Award Notice Date
    7/9/2008 - 15 years ago
Organizations

Breathing Tube Position and Patency Monitoring System

[unreadable] DESCRIPTION (provided by applicant): This project will evaluate the clinical efficacy and cost savings benefits from use of an endotracheal tube (ETT) position and patency monitoring system through a prospective, randomized, controlled trial conducted at multiple clinical centers. The two years, two phase study will enroll up to 270 subjects that include neonates, children, and adults who require intubation for extended ventilatory assistance. The system operation is based on an acoustic pulse-echo technique that non-invasively probes ETTs with sound and uses the returning echoes to determine the tube's position within the patient and provide quantitative information regarding tube patency. Phase I will verify safety and feasibility in approximately 50 subjects by programming the device to continuously collect ETT position and function data while the subject is mechanically ventilated, but blinding the research team to these data. Normal "standard of care" procedures will be used to maintain proper ETT function (e.g. routine chest x-rays to confirm ETT position, suctioning). Measurable results from these procedures will be compared to the data recorded on the device to determine consistency. Adverse events will be analyzed to determine if any were device related. If the results meet the safety and feasibility endpoints, Phase II will be initiated. Phase II will consist of a prospective, 1:1 randomized study of approximately 220 subjects in which the device will be used as a primary means to monitoring ETT location and function. Device data will be collected in addition to the standard of care measures performed on each subject. The primary hypothesis being investigated in this study is that use of this device will decrease the overall respiratory adverse event rate associated with mechanical ventilation. Secondarily, the data will be analyzed to determine if this device reduces adverse events associated with ETT position or function and predicts ETT-related adverse events prior to their occurrence. SonarMed's intelligent endotracheal tube (ETT) monitoring system has the potential to establish a new paradigm in the standard of care for airway management. It will enable clinicians to move from the current reactive approach that provides corrective action only in response to indirect indications of ETT complications (patient in respiratory distress), towards a more proactive methodology where immediate notification of high risk ETT conditions (ETT on verge of extubation) can be used to anticipate and thereby prevent adverse events. [unreadable] [unreadable] [unreadable]

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    1000000
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:1000000\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    SONARMED, INC.