Bright and Fast Sensors for Radioluminescence Microscopy of Single Living Cells

Information

  • Research Project
  • 8712913
  • ApplicationId
    8712913
  • Core Project Number
    R43GM110888
  • Full Project Number
    1R43GM110888-01
  • Serial Number
    110888
  • FOA Number
    PA-13-234
  • Sub Project Id
  • Project Start Date
    6/1/2014 - 10 years ago
  • Project End Date
    5/31/2015 - 9 years ago
  • Program Officer Name
    FLICKER, PAULA F.
  • Budget Start Date
    6/1/2014 - 10 years ago
  • Budget End Date
    5/31/2015 - 9 years ago
  • Fiscal Year
    2014
  • Support Year
    01
  • Suffix
  • Award Notice Date
    5/23/2014 - 10 years ago

Bright and Fast Sensors for Radioluminescence Microscopy of Single Living Cells

DESCRIPTION (provided by applicant): Radioluminescence microscopy is a newly developed method for imaging radionuclide uptake in live single cells. Current methods of radiotracer imaging are limited to measuring the average radiotracer uptake in large cell populations and, as a result, lack the ability to quantify cell-to-cell variations. With the new radio- luminescence microscopy technique, however, it is possible to visualize radiotracer uptake within individual cells in a fluorescence microscope environment. The goal of this project is to develop a revolutionary innovation in a key component used in this technique. This key part in the radioluminescence microscopy imaging system is the scintillator that converts ionizing beta radiation into optical photons that are imaged with a CCD camera. In this work, an improved scintillator will be developed, specifically for use in a radioluminescence microscopy system that will offer unprecedented sensitivity and spatial resolution. Such a technological advance has the potential for widespread use in research and in hospitals, providing a means to characterize how properties specific to individual cells (e.g. gene expression, cell cycle, cell damage, and cel morphology) affect the uptake and retention of radiotracers. Higher spatial resolution will allow single cells to be probed in situ, in dense tissue sections, and will dramatically improve the throughput of the instruments, allowing thousands of cells to be imaged at once. These new capabilities will be critical to help researchers better understand the behavior of rare single cels such as stem cells or drug-resistant cells. The objectives of this Phase I project is the demonstrate the feasibility of successfully depositing of thin (micron-scale) films of a highly dense transparent scintillator, europium-activated lutetium oxide (Lu2O3:Eu). This material has the highest density (9.5 g/cm3) of any known scintillator, high effective atomic number (67.3), excellent light output, and an emission wavelength (610 nm) for which Si sensors have a very high quantum efficiency. Select scintillator specimens will be integrated into a radioluminescence microscope demonstrating improved performance in this exciting new imaging system. Ultimately, the goal is to commercialize this technology as a radioluminescence-enabled imaging dish, which will have a standard form factor but will include a thin coating of the Lu2O3:Eu scintillator at the bottom. As such, the technological innovation will provide a valuable new tool to researchers allowing unprecedented localization of radiotracer uptake down to single living cells. This new innovative technology will have widespread use as an addition to current fluorescence microscope instruments in use today and thus will have great commercial potential.

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R43
  • Administering IC
    GM
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    186680
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    859
  • Ed Inst. Type
  • Funding ICs
    NIGMS:186680\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    RADIATION MONITORING DEVICES, INC.
  • Organization Department
  • Organization DUNS
    073804411
  • Organization City
    WATERTOWN
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    024724624
  • Organization District
    UNITED STATES