Cerbral Perfusion Imaging using Cone Beam Computed Tomography

Information

  • Research Project
  • 7537917
  • ApplicationId
    7537917
  • Core Project Number
    R43NS062602
  • Full Project Number
    1R43NS062602-01A1
  • Serial Number
    62602
  • FOA Number
    PA-07-89
  • Sub Project Id
  • Project Start Date
    8/1/2008 - 16 years ago
  • Project End Date
    7/31/2009 - 15 years ago
  • Program Officer Name
    GOLANOV, EUGENE V
  • Budget Start Date
    8/1/2008 - 16 years ago
  • Budget End Date
    7/31/2009 - 15 years ago
  • Fiscal Year
    2008
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    7/21/2008 - 16 years ago
Organizations

Cerbral Perfusion Imaging using Cone Beam Computed Tomography

[unreadable] DESCRIPTION (provided by applicant): Stroke is the leading cause of adult disability and third leading cause of death in the United States with approximately 700,000 new or recurrent strokes each year. Perfusion Computed Tomography (PCT) provides maps of parameters such as cerebral blood flow, volume and transit times. These parameters can be used to distinguish between ischemic and hemorrhagic stroke, to determine the location and extent of the hypoperfused area, and also to differentiate between the irreversibly damaged and salvageable tissue. We will investigate the feasibility of implementing PCT on a mobile, flat-panel detector, cone-beam CT (CBCT) system. Using such a platform will address two shortcomings of current PCT technology: lack of whole-brain coverage and limited accessibility in the emergency department and intensive care unit. We will focus on two issues: 1) relatively low scanning speed of flat-panel-based CBCT, which may hamper temporal sampling of contrast dynamics; and 2) increased projection noise and limited dynamic range of flat-panel detectors. In this project we will first experimentally investigate the characteristics of flat- panel detectors for imaging iodine enhanced vessels with respect to image noise and contrast. In the second stage of the research we will develop and validate a model- based, iterative algorithm for reconstruction of dynamic projection data acquired with relatively slowly rotating systems. PUBLIC HEALTH RELEVANCE: Stroke is the leading cause of adult disability and third leading cause of death in the United States with approximately 700,000 new or recurrent strokes each year. The mobile flat-panel-based CT system capable of perfusion imaging proposed here will allow for rapid assessment of neurovascular function of the whole brain directly in the emergency department. This tool may bring about improvements in stroke diagnosis and provide important support for treatment decisions, thus greatly improving outcome for acute strokes victims. [unreadable] [unreadable] [unreadable]

IC Name
NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE
  • Activity
    R43
  • Administering IC
    NS
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    100416
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    853
  • Ed Inst. Type
  • Funding ICs
    NINDS:100416\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    XORAN TECHNOLOGIES, INC.
  • Organization Department
  • Organization DUNS
    018381405
  • Organization City
    ANN ARBOR
  • Organization State
    MI
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    481087936
  • Organization District
    UNITED STATES