Clinical feasibility of a non-invasive, low-cost wearable for measuring air trapping in COPD

Information

  • Research Project
  • 10080272
  • ApplicationId
    10080272
  • Core Project Number
    R41HL152769
  • Full Project Number
    1R41HL152769-01A1
  • Serial Number
    152769
  • FOA Number
    PA-19-271
  • Sub Project Id
  • Project Start Date
    7/20/2020 - 4 years ago
  • Project End Date
    6/30/2021 - 3 years ago
  • Program Officer Name
    PUNTURIERI, ANTONELLO
  • Budget Start Date
    7/20/2020 - 4 years ago
  • Budget End Date
    6/30/2021 - 3 years ago
  • Fiscal Year
    2020
  • Support Year
    01
  • Suffix
    A1
  • Award Notice Date
    7/19/2020 - 4 years ago
Organizations

Clinical feasibility of a non-invasive, low-cost wearable for measuring air trapping in COPD

ABSTRACT Chronic Obstructive Pulmonary Disease (COPD) is the third leading cause of hospitalization in the US. Exacerbations - a worsening or ?flare up? of symptoms - cause most COPD hospitalizations. Since most exacerbations can be treated with changes of inhalers and/or oral medications, at-home detection of lung function deterioration may facilitate earlier intervention and help delay or prevent hospitalizations. The Standards of Care for monitoring lung function are spirometry, plethysmography, and CT scan. However, these are expensive methods and unsuited for continuous monitoring or at-home use. Various patient self-monitoring approaches have been tried, for example, pulse oximetry, respiratory rate monitoring, and peak flow metering, but their efficacy in reducing hospitalizations has been limited. A common finding for all forms of COPD is air trapping, defined, as an abnormal increase in the volume of air remaining in the lungs after exhalation is complete. A body of evidence definitively shows that air trapping increases during exacerbations and decreases when exacerbations resolve. Recent reports show that air trapping is an earlier harbinger of deteriorating lung function than spirometric changes, and can be measured by low-frequency ultrasound (1-40 kHz). Acoustic monitoring of air trapping could provide clinicians with a non- invasive tool when medical intervention is needed to avoid unnecessary ER visits and hospitalizations. Respira Labs has developed a low-cost, non-invasive, acoustic-based wearable device that can continually monitor lung resonance: Sylvee. The device uses known acoustic-based technology with machine- learning algorithms to detect minor changes in lung resonance, which our preliminary results suggest correspond to changes in air trapping. The overall objective of this project is to validate Sylvee's air trapping algorithms in a cohort of 20 healthy controls and 40 COPD patients with and without air trapping, respectively. In Aims 1 and 2, we will miniaturize and add sensors to the Sylvee device and develop a user interface (UI) and a mobile application. In Aims 3 and 4, we will create an Air Trapping Index Report and validate it in a cross-sectional study vis-à-vis whole body plethysmography as a control. Results of this project provide a go/no-go development decision based on device function. We can apply these results in STTR Phase II, in a larger clinical study to evaluate Sylvee as an at-home monitoring system, with a goal of reducing hospitalizations by at least 30%. Ultimately, Sylvee will allow physicians to remotely monitor their patients' lung function and adjust their medications to reduce healthcare costs and improve patients' quality of life.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R41
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    350000
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    838
  • Ed Inst. Type
  • Funding ICs
    NHLBI:350000\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    RESPIRA LABS, LLC
  • Organization Department
  • Organization DUNS
    081197476
  • Organization City
    MOUNTAIN VIEW
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    94040
  • Organization District
    UNITED STATES