Cryocooled Biomagnetometer

Information

  • Research Project
  • 7538209
  • ApplicationId
    7538209
  • Core Project Number
    R43EB008926
  • Full Project Number
    1R43EB008926-01
  • Serial Number
    8926
  • FOA Number
    PA-07-80
  • Sub Project Id
  • Project Start Date
    9/1/2008 - 16 years ago
  • Project End Date
    4/30/2009 - 15 years ago
  • Program Officer Name
    SWAIN, AMY L
  • Budget Start Date
    9/1/2008 - 16 years ago
  • Budget End Date
    4/30/2009 - 15 years ago
  • Fiscal Year
    2008
  • Support Year
    1
  • Suffix
  • Award Notice Date
    8/19/2008 - 16 years ago

Cryocooled Biomagnetometer

[unreadable] DESCRIPTION (provided by applicant): We propose to study and determine the feasibility of developing a novel approach for a cryocooled multichannel large biomagnetic system. Mechanical refrigeration is the only technique capable of providing the economical gains involved in cooling large biomagnetic systems. The proposed design would make these systems more economically attractive to run and maintain as well as reducing the logistics associated with constant handling of liquid helium. Biomagnetometers installations based on SQUID operation have always required liquid cryogens to [unreadable] operate. Typically this operation can run a cost in the range from 0.5 - 2.5 million dollars depending on the type of system and number of detection channels. Thus a typical MEG installation will consume $20,000 -$40,000 of liquid helium annually. While the economics of liquid helium have not been a major inhibitor to the diffusion of biomagnetic instrumentation in the past, scarcity and increasing costs could change that. Mechanical closed cycle refrigerators has become an alternative to the use of liquid cryogens. These include reduction of operating costs, use in remote locations, and operation in non-vertical orientations, avoiding interruptions in cryogen deliveries, safety, and the convenience of not having to transfer every few days. There are two main obstacles to using closed cycle refrigeration with SQUIDs. The first is the mechanical movement that (ultimately) causes the detection coils to move in the Earth's magnetic field. The second is the magnetic signature due to the moving parts of the cryocooler's cold head and compressor. The proposed design could significantly increase the market for large biomagnetometer systems not only in the US but also especially in European and Asian countries because of the lack of foreign helium gas source causing the associated costs to be twice the US costs. In addition, a helium shortage is developing due to increasing demand in industrial. [unreadable] [unreadable] [unreadable]

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R43
  • Administering IC
    EB
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    87601
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    389
  • Ed Inst. Type
  • Funding ICs
    NCRR:87040\NIBIB:561\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    TRISTAN TECHNOLOGIES, INC.
  • Organization Department
  • Organization DUNS
    060887812
  • Organization City
    SAN DIEGO
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    92121
  • Organization District
    UNITED STATES