Deploying retinal birefringence imaging in to the clinic for pediatric vision screening

Information

  • Research Project
  • 9558081
  • ApplicationId
    9558081
  • Core Project Number
    R44EY027633
  • Full Project Number
    2R44EY027633-02
  • Serial Number
    027633
  • FOA Number
    PA-17-302
  • Sub Project Id
  • Project Start Date
    2/1/2017 - 7 years ago
  • Project End Date
    5/31/2020 - 4 years ago
  • Program Officer Name
    WUJEK, JEROME R
  • Budget Start Date
    6/1/2018 - 6 years ago
  • Budget End Date
    5/31/2019 - 5 years ago
  • Fiscal Year
    2018
  • Support Year
    02
  • Suffix
  • Award Notice Date
    5/28/2018 - 6 years ago
Organizations

Deploying retinal birefringence imaging in to the clinic for pediatric vision screening

Project Summary/Abstract ! Amblyopia is vision loss caused by suppression of a structurally normal eye due to strabismus, asymmetric refraction (anisometropia), or deprivation. Treatment becomes challenging if not caught by age 7, but half of all patients in the US are undetected and untreated until after it is too late, making it the leading cause of preventable vision loss. Rebion has developed retinal birefringence scanning (RBS) into a commercial product, the RBS-based Pediatric Vision Scanner (PVS), which detects amblyopia and strabismus with 94% accuracy, compared with 69% accuracy of non-RBS methods. However RBS-based scanning faces challenges ? including the need for costly moving parts and the presence of significant background noise necessitating background measurements ? that may limit widespread commercial acceptance of this technology. With prior Phase I NEI funding (EY 027633) Rebion has successfully built a new approach toward assessment of retinal birefringence that we call retinal birefringence imaging (RBI). Like RBS, this approach measures the polarization signature produced by the Henle nerve fibers at the center of fixation of the retina, thus objectively detecting ocular fixation, but it can be implemented with no moving parts and without the need for background measurements. Imaging are obtained in a fraction of a second (vs. 2.5 seconds of scanning required for an accurate RBS measurement.) The design also allows for future incorporation of a photoscreening channel for assessment of refractive error in synchrony with detection of amblyopia and strabismus. In this Phase II study, we will test the hypothesis that the performance of the RBI device can match the sensitivity, specificity, and accuracy of the commercially available PVS device in a large-scale clinical trial. The RBI device built with Phase I funding will be deployed with the Retina Foundation of the Southwest, and tested in both the enriched population of eye care clinics, as well as un-enriched populations of primary care clinics. The disease prevalence of primary care clinics will more closely mimic the disease prevalence of the general population, while the disease prevalence of eye clinics will allow the study to carry statistical significance in the most cost-effective use of NIH funds. Successful execution of project milestones will lead to an immediate transition to regulatory clearance with FDA and manufacturing with Rebion's contract manufacturer. This advance will greatly reduce expenses and complexities related to pediatric vision screening.

IC Name
NATIONAL EYE INSTITUTE
  • Activity
    R44
  • Administering IC
    EY
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    542407
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    867
  • Ed Inst. Type
  • Funding ICs
    NEI:542407\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    REBISCAN, LLC
  • Organization Department
  • Organization DUNS
    831265967
  • Organization City
    BOSTON
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    02109
  • Organization District
    UNITED STATES