Development Lateral Flow Assay

Information

  • Research Project
  • 7928388
  • ApplicationId
    7928388
  • Core Project Number
    R43HL103378
  • Full Project Number
    1R43HL103378-01
  • Serial Number
    103378
  • FOA Number
    RFA-OD-09-009
  • Sub Project Id
  • Project Start Date
    6/1/2010 - 15 years ago
  • Project End Date
    5/31/2012 - 13 years ago
  • Program Officer Name
    MITCHELL, PHYLLIS
  • Budget Start Date
    6/1/2010 - 15 years ago
  • Budget End Date
    5/31/2012 - 13 years ago
  • Fiscal Year
    2010
  • Support Year
    1
  • Suffix
  • Award Notice Date
    4/7/2010 - 15 years ago
Organizations

Development Lateral Flow Assay

DESCRIPTION (provided by applicant): The goal of this project is to develop a lateral flow assay for detecting complement levels and complement activation status in a patient. This assay will give results in seconds versus either hours or days that normal complement lab assays have. It also will give more accurate results than conventional assays. The complement system is a group of more than 30 serum and membrane proteins that comprise an important effector arm of the innate immune system. However, complement can also damage host tissue, leading to its being termed a "double-edged sword." Complement plays a role in many, and diverse, diseases such as age- related macular degeneration (AMD), arthritis, stroke, trauma, and more. Altogether more than 30 million Americans suffer from complement-involved disorders. One problem facing detecting and treating these diseases are fast and reliable assays. For some indications such as trauma massive complement activation can occur within minutes of injury. This often proceeds a cytokine storm that can cause shock or organ failure. Knowing the cytokine storm is imminent allows preemptive treatment. In other cases the samples must be shipped for complement is very labile and does not store well at temperatures warmer than -80C. A lateral flow assay will allow immediate accurate results that are not available to most labs at present. PUBLIC HEALTH RELEVANCE: We intend to develop a point of care, lateral flow assay for the detection and quantification of complement component 3 and its metabolites. This is to address the variability of other assay formats caused by the duration of the assay, and the test article handling and storage.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    199998
  • Sub Project Total Cost
  • ARRA Funded
    True
  • CFDA Code
    701
  • Ed Inst. Type
  • Funding ICs
    NHLBI:199998\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    KYPHA, INC.
  • Organization Department
  • Organization DUNS
    832251537
  • Organization City
    SAINT LOUIS
  • Organization State
    MO
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    63108
  • Organization District
    UNITED STATES