Development of a Neurovascular Magnetic Particle Imaging system with sub-millimeter resolution and real time speed for non-radiative 3D perfusion angiography

Information

  • Research Project
  • 9049379
  • ApplicationId
    9049379
  • Core Project Number
    R43DA041814
  • Full Project Number
    1R43DA041814-01A1
  • Serial Number
    041814
  • FOA Number
    PA-14-071
  • Sub Project Id
  • Project Start Date
    9/15/2015 - 8 years ago
  • Project End Date
    8/31/2016 - 7 years ago
  • Program Officer Name
    BOUGH, KRISTOPHER J.
  • Budget Start Date
    9/15/2015 - 8 years ago
  • Budget End Date
    8/31/2016 - 7 years ago
  • Fiscal Year
    2015
  • Support Year
    01
  • Suffix
    A1
  • Award Notice Date
    9/14/2015 - 8 years ago
Organizations

Development of a Neurovascular Magnetic Particle Imaging system with sub-millimeter resolution and real time speed for non-radiative 3D perfusion angiography

? DESCRIPTION (provided by applicant): There is a clinical need for new neurovascular imaging techniques for the diagnosis, staging, and monitoring of acute stroke and sub-acute stenoses, arterial-venous malformations (AVMs), and aneurysms, among others. Together, these etiologies frequently manifest in acute stroke and kill over 130,000 people per year with an estimated cost the US healthcare system of over 36.5 billion dollars per year. A reliable and non-invasive neurovascular stress test, similar in concept to a cardiac stress test, would revolutionize cerebrovascular imaging and stroke prevention. It is well known that perfusion imaging, combined with a means of altering cerebral perfusion pressure or cerebrovascular resistance, can measure a patient's cerebrovascular reserve and predict the risk of stroke. Current neurovascular imaging techniques suffer from limitations in radiation exposure, safety, speed, sensitivity, and specificity that prevent their use in measuring cerebrovascular reserve. Magnetic particle imaging (MPI) is a new imaging technology that answers a clinical need for a safe, rapid 3D perfusion and 3D angiography technique without ionizing radiation or toxic tracers to image intracranial diseases such as stenosis (stroke), aneurysm, vasospasms and malformations. The MPI tracer is made with Iron Oxide (SPIO), significantly safer than Iodine (used in CT and fluoroscopy), and Gadolinum (used in MRI). The safe tracer and absence of harmful radiation leads to reduced long term medical costs for patient undergoing diagnostic angiography, and especially patients undergoing repeated diagnostic angiography procedures associated with long term care. MPI produces absolutely no signal from overlying tissues creating a positive contrast and quantitative angiography images or real time perfusion with unprecedented contrast to- noise and signal-to-noise. Successful completion of a human brain imager will mark the beginning of a new field of diagnostic imaging comparable in scope to the introduction of MRI, CT, or Ultrasound. This project aims to develop the first high resolution real time MPI system tailored for clinical cerebrovascular imaging. The proposed system will be the world's highest sensitivity and highest resolution tomographic MPI scanner. In Phase I of this SBIR, we will complete the main magnet design, build a 1/4 scale prototype, and develop our manufacturing plan. In Phase II we will construct the magnet and obtain phantom and animal images. In Phase III we will perform animal and then human testing

IC Name
NATIONAL INSTITUTE ON DRUG ABUSE
  • Activity
    R43
  • Administering IC
    DA
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    223825
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    279
  • Ed Inst. Type
  • Funding ICs
    NIDA:223825\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    MAGNETIC INSIGHT, INC.
  • Organization Department
  • Organization DUNS
    078791637
  • Organization City
    NEWARK
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    945604806
  • Organization District
    UNITED STATES