Development of a versatile robotic radiation therapy system

Information

  • Research Project
  • 9671861
  • ApplicationId
    9671861
  • Core Project Number
    R44CA183390
  • Full Project Number
    5R44CA183390-04
  • Serial Number
    183390
  • FOA Number
    PA-16-302
  • Sub Project Id
  • Project Start Date
    6/19/2016 - 8 years ago
  • Project End Date
    3/31/2020 - 4 years ago
  • Program Officer Name
    EVANS, GREGORY
  • Budget Start Date
    4/1/2019 - 5 years ago
  • Budget End Date
    3/31/2020 - 4 years ago
  • Fiscal Year
    2019
  • Support Year
    04
  • Suffix
  • Award Notice Date
    3/12/2019 - 5 years ago

Development of a versatile robotic radiation therapy system

Significance: Robotic radiotherapy using extensively non-coplanar beams has been shown effective to significantly improve radiation therapy dosimetry, leading to improved treatment outcomes. However, the current implementation of this technique by CyberKnife is inefficient and not dosimetrically optimal. This has severely limited both the number of patients eligible for robotic radiotherapy and the achievable clinical outcome for those who have been treated. In order to overcome these limitations, a novel robotic radiotherapy system will be developed that can efficiently utilize the full potential of the non-coplanar delivery space to treat the majority of radiotherapy patients. Innovation: The proposed system is highly innovative in the following aspect: 1) Integrated beam orientation and fluence optimization. 2) Significantly more compact linac to allow posterior beams. 3) Flexible field sizes and MLC resolution to efficiently treat most target sizes. 4) Volumetric imaging and real-time IGRT will be implemented. This project is proposed to design the hardware and software platforms materializing such a robotic radiotherapy system. In order to reduce the gantry size, both the linac length and the distance between the source and the MLC need to be significantly reduced. A new 3 MV source has been designed to reduce linac length and provide the required dose rate for treatment. The physical MLC leaf thickness cannot be substantially thinner than 1 mm. To achieve a high MLC resolution at the treatment distance, a spacer is used in CyberKnife between the primary collimator and the MLC, increasing the gantry dimension. This proposed system will eliminate the spacer but vary the focus-to-tumor distances (FTD) to achieve desired field size and MLC resolution. This requires optimization in an enormous solution space, a capacity uniquely demonstrated by the 4? algorithm. Aims: 1a: Build the 3MV linac that can produce 800 cGy/min at 100 cm. 1b. Mount the linac on an industrial robot and test its mechanical robustness. 1c. Integrate a micro multi-leaf collimator (MLC). 2a. Develop a global optimal direct aperture solution for the static intensity modulated radiotherapy (IMRT). 2b. Develop a global volumetric modulated arc therapy (gVMAT) solution. 2c. Develop a navigation algorithm for the robot to travel and deliver the radiation efficiently. 3a. Perform safety and collision model test. 3b. Dosimetry end-to-end testing. 3c. QA test. Impact: Successfully achieving these three aims will provide a prototype to prove the feasibility of the versatile robotic system for radiotherapy. It will be scientifically and clinically significant, positioning the system well for further commercial development.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R44
  • Administering IC
    CA
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    432270
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    393
  • Ed Inst. Type
  • Funding ICs
    NCI:432270\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    RADIABEAM TECHNOLOGIES, LLC
  • Organization Department
  • Organization DUNS
    140789137
  • Organization City
    SANTA MONICA
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    904044021
  • Organization District
    UNITED STATES