DUAL-TUNED PROBE FOR MRI/MRS OF THE HUMAN BRAIN

Information

  • Research Project
  • 6393903
  • ApplicationId
    6393903
  • Core Project Number
    R44NS037273
  • Full Project Number
    5R44NS037273-03
  • Serial Number
    37273
  • FOA Number
  • Sub Project Id
  • Project Start Date
    6/15/1998 - 26 years ago
  • Project End Date
    8/31/2003 - 21 years ago
  • Program Officer Name
    KELTY, MIRIAM F.
  • Budget Start Date
    9/1/2001 - 23 years ago
  • Budget End Date
    8/31/2003 - 21 years ago
  • Fiscal Year
    2001
  • Support Year
    3
  • Suffix
  • Award Notice Date
    9/11/2001 - 23 years ago

DUAL-TUNED PROBE FOR MRI/MRS OF THE HUMAN BRAIN

In Phase I, a hybrid quadrature, dual-tuned (31P-1H) probe with nearly identical field-of-view, ideal for 31H decoupled 31P spectroscopy of the entire adult bran was prototyped at 1.5T. Phantom tests and volunteer evaluations showed improved performance and extended coverage at the low gamma nucleus (31P) over the previous design. Phase II will involve prototype developments based on the new design, followed by coil comparisons and extensive phantom/volunteer evaluations at both the NMR frequencies (31P, 1H). Based on the success of the adult coil design, custom coils for imaging the pediatric brain and the adult forearm muscle will be prototyped at 1.5T. Our coil design will be upscaled in frequency to operate as a 23Na-1H head coil at 4.0T. Research on dual-tuned quadrature surface coil designs will be performed at 4.0T. Based on the success at 1.5 and 4.0T, 3.0T coils will be developed. A goal of this research is to improve image quality and spectroscopic representation of the x-nucleus over the brain in one patient setting, which will aid in the clinical diagnosis. This we believe will be of a substantial benefit to mankind. PROPOSED COMMERCIAL APPLICATION: Research and clinical applications include non-ionizing brain imaging when compared to ionizing radiation techniques such as PET, SPECT, etc. This project will provide a significant improvement to the NMR RF coil technology including sequence and technique optimizations. if clinical value is demonstrated NMR systems based on this technology will find widespread applications in the areas of stroke/epilepsy mitochondrial cytopathies cancer AIDS multiple sclerosis and neurodegenerative brain diseases.

IC Name
NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE
  • Activity
    R44
  • Administering IC
    NS
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    419265
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    853
  • Ed Inst. Type
  • Funding ICs
    NINDS:419265\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ADVANCED IMAGING RESEARCH, INC.
  • Organization Department
  • Organization DUNS
    964729032
  • Organization City
    CLEVELAND
  • Organization State
    OH
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    44114
  • Organization District
    UNITED STATES