ELECTROCHEMICAL BIOSENSOR OF CARDIAC MARKERS

Information

  • Research Project
  • 6072572
  • ApplicationId
    6072572
  • Core Project Number
    R43HL064481
  • Full Project Number
    1R43HL064481-01
  • Serial Number
    64481
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/22/2000 - 24 years ago
  • Project End Date
    3/21/2001 - 23 years ago
  • Program Officer Name
    CHEUNG, GEOFFREY P.
  • Budget Start Date
    9/22/2000 - 24 years ago
  • Budget End Date
    3/21/2001 - 23 years ago
  • Fiscal Year
    2000
  • Support Year
    1
  • Suffix
  • Award Notice Date
    9/21/2000 - 24 years ago
Organizations

ELECTROCHEMICAL BIOSENSOR OF CARDIAC MARKERS

Development of a novel immunochromatographic electrochemical biosensor(IEB) is proposed for simultaneous quantitation of Troponin-I, Myoglobin and CK-MB, which have been reported to be important indexes in the diagnosis of myocardial infraction. Such biosensor using electrochemical detectors will avoid optical interference in the current immunoassays, and will provide more accuracy and sensitivity to rapidly quantify analytes. Our preliminary results using the proposed methodology for quantitation of myoglobin demonstrated several advantages over the current existed method such as high sensitivity, reproducibility, rapidity and convenience in use. We propose to further optimize this novel method for simultaneous quantitation of the above mentioned cardiac bio-markers, and develop a portable biosensor in point-of-care application. The proposed biosensor will consist of an immunochromatographic strip which produces immuno-complexes of these cardiac markers with their specific antibodies labeled with different metal ions and an electrochemical detector which quantifies the amounts of these metal ions in the complex. Design of the IEB will be carefully developed, and simultaneous quantitation of metal ions by the electrode in the test strips will also be evaluated and optimized. Such biosensor will provide essential information for proper clinical decision, and thus greatly improve the quality of coronary care. PROPOSED COMMERCIAL APPLICATIONS: About 16 million cardiac examinations were conducted annually in the United States. A method with rapidity, high specificity and sensitivity, clinical accuracy is urgent to be developed for simultaneous quantitation of the cardiac markers in coronary care. The proposed immunochromatographic electrochemical biosensor is expected to provide these characteristics of myocardial infarction diagnosis at emergency room or coronary care units. Such biosensor will provide a low cost, highly efficient, clinically accurate and simple operation without technical training, and thus will have additional potential in commercial applications.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    120304
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:120304\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    INTEC SCIENCE, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    BRISBANE
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    94005
  • Organization District