Endotracheal Tube Monitor for Neonates

Information

  • Research Project
  • 8055883
  • ApplicationId
    8055883
  • Core Project Number
    R43HL105264
  • Full Project Number
    5R43HL105264-02
  • Serial Number
    105264
  • FOA Number
    RFA-HD-09-017
  • Sub Project Id
  • Project Start Date
    4/1/2010 - 15 years ago
  • Project End Date
    3/31/2013 - 12 years ago
  • Program Officer Name
    BLAISDELL, CAROL J
  • Budget Start Date
    4/1/2011 - 14 years ago
  • Budget End Date
    3/31/2013 - 12 years ago
  • Fiscal Year
    2011
  • Support Year
    2
  • Suffix
  • Award Notice Date
    3/4/2011 - 14 years ago

Endotracheal Tube Monitor for Neonates

DESCRIPTION (provided by applicant): Each year, at least 10,000 critically sick babies in respiratory failure are intubated for ventilator support. For these babies, intubation bears major health risks such as airway emergencies, cardiopulmonary arrest, pneumothoraces. Neonates, however young, can be quite active, leading to undesirable tube movement and unplanned extubations. To date, there exists no reliable way of assessing Endotracheal Tube (ETT) position in real time without excessive X-ray radiation doses. Episodic assessment by X-rays of the baby's head and neck used to determine tube position would not detect a mal positioned tube in real time. In fact, such assessments are often performed late, in response to bedside alarms that continuous monitor for oxygen desaturations or poor ventilation. At this point, the effects of tube mal-position have already had detrimental effects on lung recruitment and gas exchange. An easy-to-use real-time sensor that indicates whether an endotracheal tube has moved out of 'good position'is needed. We propose to develop a device entitled Endotracheal Tube Monitor (ETM) that can detect the changes in the ETT position and help the nurse to reposition the tube. Artann Laboratories developed a proof-of-principle optical system that can track the motion of a tube accurately and remotely through layers of tissue. The system was successfully tested in laboratory studies and in an in vivo animal model. In the proposed project, the ETM technology will be further tested and refined. The objectives of the study include: design, assemble and validate ETM alpha-prototype;conduct cadaver studies on sensitivity of ETM to the motion of the ETT;and design ETM beta-prototype based on the feedback from the laboratory and cadaver studies. The deliverables at the end of the two year study are ETM's bench validated performances, report on ease-of-use, accuracy of measurement, and individual and operator-to- operator variations, and detailed design and documentation for building the ETM beta- prototype for Phase II clinical studies. The main ETM market opportunity is in an increased safety of neonate mechanical ventilator support and a substantial cost reduction to an existing method of ETT monitoring. PUBLIC HEALTH RELEVANCE: Each year, at least 10,000 critically sick babies in respiratory failure are intubated for ventilator support. For these babies, intubation bears major health risks such as airway emergencies, cardiopulmonary arrest and pneumothoraces, To date, there exists no reliable and easy way of assessing endotracheal tube position in real time without chest radiology. The Endotracheal Tube Monitor (ETM), a compact, inexpensive and easy-to- use optical device proposed in this application will allow endotracheal tube position monitoring without the use of hazardous X-ray radiation.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    223219
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:223219\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZHD1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ARTANN LABORATORIES, INC.
  • Organization Department
  • Organization DUNS
    959147026
  • Organization City
    TRENTON
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    086181414
  • Organization District
    UNITED STATES