Equilibrium Socket System - ESS

Information

  • Research Project
  • 7671681
  • ApplicationId
    7671681
  • Core Project Number
    R43HD061166
  • Full Project Number
    1R43HD061166-01
  • Serial Number
    61166
  • FOA Number
    PA-08-050
  • Sub Project Id
  • Project Start Date
    3/16/2009 - 15 years ago
  • Project End Date
    3/15/2010 - 14 years ago
  • Program Officer Name
    QUATRANO, LOUIS A
  • Budget Start Date
    3/16/2009 - 15 years ago
  • Budget End Date
    3/15/2010 - 14 years ago
  • Fiscal Year
    2009
  • Support Year
    1
  • Suffix
  • Award Notice Date
    3/16/2009 - 15 years ago

Equilibrium Socket System - ESS

DESCRIPTION (provided by applicant): The fit of a prosthesis determines the function of the user to a great degree. In the extreme, a painful fit will result in non-use of the prosthesis. Diurnal, menstrual and other fluctuations in body weight lead to noticeable changes in comfort and function of a prosthesis. As a consequence, the relative goodness of socket fit determined by socket volume is of paramount concern in the daily lives of persons with limb loss The objective of the proposed work is to create a Equilibrium Socket System (ESS) for Lower Limb Prostheses). Preliminary work undertaken by the OrthoCare Innovations team has resulted in identification of an approach that may be developed into a clinically relevant, commercially viable system for dynamically adjusting prosthesis sockets. While both socket volume, and vacuum suspension systems have been developed previously, the approaches taken often work against each other and sometimes against normal physiological change. The unique feature of the ESS is that combines a user adjustable level of dynamic volume accommodation using a very simple mechanism, coupled with a silent, dynamically adjusting vacuum suspension system. The system will allow both the prosthetist and the patient to control socket volume changes and suspension in a way that accommodates normal volume fluctuation. The technology will enable the patient to participate more fully by directly controlling adjustments based on what they feel. In the proposed work, we will design and build the prototype system, evaluate performance and feasibility with human subjects, and review the results with the subjects and colleagues in clinical prosthetics. PUBLIC HEALTH RELEVANCE: This project will improve the fit and function of prostheses by creating a dynamically and automatically adjusting socket interface with the amputated limb. The technology will allow the prosthesis user to adjust the firmness of the fit of their prosthesis quickly, easily, and in a more precisely controlled manner than is currently possible.

IC Name
EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH &HUMAN DEVELOPMENT
  • Activity
    R43
  • Administering IC
    HD
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    161937
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    865
  • Ed Inst. Type
  • Funding ICs
    NICHD:161937\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ORTHOCARE INNOVATIONS, LLC
  • Organization Department
  • Organization DUNS
    801230413
  • Organization City
    OKLAHOMA CITY
  • Organization State
    OK
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    731043637
  • Organization District
    UNITED STATES