Lee, Chong-Sun; Aluri, Srinivas; Chandran, Krishnan B.; Effect of Valve Holder Flexibility on Cavitation Initiation with Mechanical Heart Valve Prostheses; Jan. 1996, Journal of Heart Valve Disease, 5(1), pp. 104-113. |
Dexter, Elisabeth U.; Aluri, Srinivas; Radcliffe, Robert R.; Zhu, Hong; Carlson, David D.; Heilman, Troy E.; Chandran, Krishnan B.; Richenbacher, Wayne E.; In Vivo Demonstration of Cavitation Potential of a Mechanical Heart Valve; May 1998, Asaio Journal. (Sep.-Oct. 1999) 45 (5), pp. 436-441. |
Chandran, K.B.; Dexter, E. U.; Aluri, S.; Richenbacher, W. E.; Negative Pressure Transients with Mechanical Heart-Valve Closure: Correlation Between In Vitro and In Vivo Results; 1998, Annals of Biomedical Engineering, vol. 26, pp. 546-556. |
Chandran, Krishnan Bala; Aluri, Srinivas; Mechanical Valve Closing Dynamics: Relationship Between Velocity of Closing, Pressure Transients, and Cavitation Initiation; Annals of Biomedical Engineering, (Nov.-Dec. 1997) 25 (6), pp. 926-938. |
Brodeur, Michael T., M.D., C.M.; Sutherland, Donald W., M.D.; Koler, Robert D., M.D.; Starr, Albert, M.D.; Kimsey, Jean A., B.S.; Griswold, Herbert E., M.D.; Red Blood Cell Survival in Patients with Aortic Valvular Disease and Ball-Valve Prostheses; Oct. 1965, Circulation, vol. XXXII, pp. 570-581. |
Rubinson, Richard M., M.D.; Morrow, Andrew G., M.D.; Gebel, Peter, M.D.; Mechanical Destruction of Erythrocytes by Incompetent Aortic Valvular Prostheses; American Heart Journal, Feb. 1966, pp. 179-186. |
Nevaril, Charles G.; Lynch, Edward C.; Alfrey, Clarence P., Jr.; Hellums, J. David; Erythrocyte Damage and Destruction Induced by Shearing Stress; May 1968, Journal of Laboratory and Clinical Medicine, pp. 784-790. |
Williams, A. R.; Viscoelasticity of the Human Erythrocyte Membrane; Biorheology, 1973, vol. 10, pp. 313-319. |
Stein, Paul D.; Sabbah, Hani N.; Measured Turbulence and Its Effect on Thrombus Formation; Circulation Research, vol. 35, Oct. 1974, pp. 608-614. |
Figliola, R.S.; Mueller, T.J.; On the Hemolytic and Thrombogenic Potential of Occluder Prosthetic Heart Valves From In-Vitro Measurements; Journal of Biomechanical Engineering, May 1981, vol. 103, pp. 83-89. |
Sallam, Ahmed M.; Hwang, Ned H.C.; Human Red Blood Cell Hemolysis in a Turbulent Shear Flow: Contribution of Reynolds Shear Stresser; Biorheology, 21, 1984, pp. 783-797. |
Hanle, D.D.; Harrison, E.C.; Yoganathan, A.P.; Allen, D.T.; Corcoran, W. H.; In Vitro Flow Dynamics of Four Prosthetic Aortic Valves: A Comparative Analysis; Journal of Biomechanics, vol. 22, No. 67, 1989, pp. 597-607. |
Giersiepen, M.; Wurzinger, L.J.; Optiz, R.; Reul, H.; Estimation of Shear Stress-Related Blood Damage in Heart Valve Prostheses—in vitro Comparison of 25 Aortic Valves; 1990, pp. 300-306. |
Lamson, Theodore C.; Frangos, John A.; Deutsch, Steven; Geselowitz, David B.; Tarbell, John M.; Blood Damage in Regurgitant Flow Through a Closed Prosthetic Heart Valve, Bioprocess Engineering Symposium—1992, BED-vol. 23, pp. 13-17. |
Rand, R. P.; Mechanical Properties of the Red Cell Members, Biophysical Journal, vol. 4, 1964, pp. 303-316. |
Bull, B.S.; Rubenberg, M. L.; Dacie, J.V.; Brain, M.C.; Microangiopathic Haemolytic Anaemia: Mechanisms of Red-Cell Fragmentation: in Vitro Studies; Brit. J. Haemat., 1968, pp. 643-652. |
Sallam, A.M.; Hwang, N.H.C.; Turbulent Strain Rate and Red Blood Cell Hemolysis; 36th ACEMB, Sep. 1983, p. 80. |