High-Density Liquid Crystal Polymer Cochlear Electrodes

Information

  • Research Project
  • 6657260
  • ApplicationId
    6657260
  • Core Project Number
    R44DC004614
  • Full Project Number
    5R44DC004614-03
  • Serial Number
    4614
  • FOA Number
  • Sub Project Id
  • Project Start Date
    7/1/2000 - 25 years ago
  • Project End Date
    9/8/2004 - 21 years ago
  • Program Officer Name
    LUETHKE, LYNN E
  • Budget Start Date
    9/9/2003 - 22 years ago
  • Budget End Date
    9/8/2004 - 21 years ago
  • Fiscal Year
    2003
  • Support Year
    3
  • Suffix
  • Award Notice Date
    6/2/2003 - 22 years ago

High-Density Liquid Crystal Polymer Cochlear Electrodes

[unreadable] DESCRIPTION (provided by applicant): In this project, high-density cochlear electrode arrays will be fabricated utilizing liquid crystal polymer (LCP) a new electronic substrate material with mechanical and electrical properties potentially well suited for advanced array fabrication and implantation. Advanced multi-layer circuit fabrication techniques incorporating blind and through-hole UV laser drilled micro-via arrays, will be utilized, increasing the number of channels and density over current generation electrodes. These arrays will exhibit significantly improved performance over current generation electrode arrays, which are made using laborious hand fabrication techniques and have limited numbers of channels. Recent developments in processor and implantation techniques demonstrate that field steering methods combined with closer placement of the array to the modilar wall in the cochlea can reduce channel interaction, motivating increasing the number of independent channels in such devices to improve performance. These arrays will support advanced processing strategies including field steering techniques and parallel, high rate, phase coherent stimulation being developed by Advanced Cochlear Systems. The new arrays combined with new processing technologies and greater pulse delivery rates made possible by field control and electrode placement may permit the delivery of two to three orders of magnitude greater information than is provided by available cochlear implant systems.

IC Name
NATIONAL INSTITUTE ON DEAFNESS AND OTHER COMMUNICATION DISORDERS
  • Activity
    R44
  • Administering IC
    DC
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    349507
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    173
  • Ed Inst. Type
  • Funding ICs
    NCMHD:344507\NIDCD:5000\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ADVANCED COCHLEAR SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    SNOQUALMIE
  • Organization State
    WA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    980659228
  • Organization District
    UNITED STATES