High energy density film capacitors for Compact Implantable Cardioverter Defibril

Information

  • Research Project
  • 7399754
  • ApplicationId
    7399754
  • Core Project Number
    R43HL091582
  • Full Project Number
    1R43HL091582-01
  • Serial Number
    91582
  • FOA Number
    PA-07-80
  • Sub Project Id
  • Project Start Date
    3/1/2008 - 16 years ago
  • Project End Date
    8/31/2008 - 15 years ago
  • Program Officer Name
    BALDWIN, TIM
  • Budget Start Date
    3/1/2008 - 16 years ago
  • Budget End Date
    8/31/2008 - 15 years ago
  • Fiscal Year
    2008
  • Support Year
    1
  • Suffix
  • Award Notice Date
    2/4/2008 - 16 years ago

High energy density film capacitors for Compact Implantable Cardioverter Defibril

[unreadable] DESCRIPTION (provided by applicant): More than 1000 Americans die every single day due to sudden cardiac arrest (SCA), which claims more lives than breast cancer, AIDS, and lung cancer combined.1 Implantable Cardioverter Defibrillators (ICD) can provide 24-hour monitoring of heart rhythm and deliver immediate effective treatment, thus can reduce overall mortality by 23% and provide 2.5 more years of life for a patient. However, the size, cost, and reliability of current ICD limit its acceptance by the patients. As a key component, the capacitor occupies more than 1/3 of the ICD volume and delivers the necessary defibrillation energy to the heart. Strategic Polymer Sciences, Inc (SPS) has developed a series of new polar fluoropolymer dielectrics that have energy density (25 J/cm3) at least four times higher than the current ICD capacitors (4-6 J/cm3) and ten times higher than other polymer film capacitors (< 2 J/cm3), therefore they can significantly reduce the size and weight of ICD (Science 313:334 (2006), "A dielectric polymer with high electric energy density and fast discharge speed").6 In addition, SPS dielectric polymers have self-healing feature, do not contain any liquid, do not require regular reforming, thus can improve the reliability of the ICD and extend the battery life. SPS is working with both capacitor and ICD manufacturers to commercialize these new materials. [unreadable] [unreadable] [unreadable]

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    98714
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:98714\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    STRATEGIC POLYMER SCIENCES, INC.
  • Organization Department
  • Organization DUNS
    784136116
  • Organization City
    STATE COLLEGE
  • Organization State
    PA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    16803
  • Organization District
    UNITED STATES