HIGH PERFORMANCE BIOSENSOR ELECTRODE MATERIALS

Information

  • Research Project
  • 6524567
  • ApplicationId
    6524567
  • Core Project Number
    R44DK056544
  • Full Project Number
    5R44DK056544-03
  • Serial Number
    56544
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/1/1999 - 26 years ago
  • Project End Date
    10/31/2003 - 22 years ago
  • Program Officer Name
    ARREAZA-RUBIN, GUILLERMO
  • Budget Start Date
    9/1/2002 - 23 years ago
  • Budget End Date
    10/31/2003 - 22 years ago
  • Fiscal Year
    2002
  • Support Year
    3
  • Suffix
  • Award Notice Date
    8/16/2002 - 23 years ago
Organizations

HIGH PERFORMANCE BIOSENSOR ELECTRODE MATERIALS

DESCRIPTION (Verbatim from the Applicant's Abstract): The GlucoWatch biographer is a device developed by Cygnus, Inc. which provides automatic, continual, and non-invasive glucose measurements for diabetics. Glucose is extracted through the skin via electro-osmosis and measured with an amperometric biosensor. Because of the small amount of glucose extracted the biosensor must achieve a much lower detection limit than conventional finger-stab glucose monitors. A high signal-to-noise ratio is especially important for accurate measurement at hypoglycemic glucose levels. This proposal focuses on the formulation of a screen printing ink for fabrication of high-performance biosensor electrodes. This ink will replicate the electrocatalytic surface determined in Phase I that optimizes and the signal-to-noise ratio by improving both the sensitivity to H2O2 and the background current. The ink is formulated from a platinum-carbon composite with a thermoplastic binder. Formulation variables to be explored will include platinum catalyst particle morphology, particle size, particle pretreatment, loading level in the ink, and ink mixing and processing parameters. Following optimization of the ink via bench top testing, biosensors using this material will be incorporated into the GlucoWatch biographer and tested on human subjects. This high-performance ink will enable enhanced product features for future generations of GlucoWatch biographer devices. PROPOSED COMMERCIAL APPLICATION: Not available

IC Name
NATIONAL INSTITUTE OF DIABETES AND DIGESTIVE AND KIDNEY DISEASES
  • Activity
    R44
  • Administering IC
    DK
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    298150
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    847
  • Ed Inst. Type
  • Funding ICs
    NIDDK:298150\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    CYGNUS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    REDWOOD CITY
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    94063
  • Organization District
    UNITED STATES