High Resolution Fluorescent Melting Curve Analysis

Information

  • Research Project
  • 6337870
  • ApplicationId
    6337870
  • Core Project Number
    R42GM060063
  • Full Project Number
    2R42GM060063-02
  • Serial Number
    60063
  • FOA Number
  • Sub Project Id
  • Project Start Date
    7/1/1999 - 25 years ago
  • Project End Date
    4/30/2003 - 21 years ago
  • Program Officer Name
    SWAIN, AMY L
  • Budget Start Date
    5/1/2001 - 23 years ago
  • Budget End Date
    4/30/2002 - 22 years ago
  • Fiscal Year
    2001
  • Support Year
    2
  • Suffix
  • Award Notice Date
    4/5/2001 - 23 years ago
Organizations

High Resolution Fluorescent Melting Curve Analysis

DESCRIPTION (Applicant's abstract): Our long-term goal is to advance instrumentation and techniques for rapid, automated and sensitive variant analysis of nucleic acids. The LightCyclerTM has been our homogenous "closed system" platform for genotyping. Fluorescent hybridization probes are included at the beginning of the reaction and are used for realtime PCR monitoring and genotyping. After rapid cycle PCR, the reaction is slowly heated (0.1 degree C/s) and products are identified by unique probe/target melting temperatures. The entire assay is performed from genomic DNA within 20 min and without any sample manipulation. Fluorescent melting curve analysis is a useful and popular method for repetitive genotyping of established mutations/polymorphisms. In phase I, we built and tested a new "high-resolution" instrument for melting curve analysis. The high-resolution melting instrument has 10-fold less measurement error than the LightCyclerTM providing increased sensitivity for mutation detection and utility in mutation scanning. In phase II, we plan to integrate the "low noise" components of the high-resolution instrument into a modified LightCyclerTM to allow both rapid amplification and smooth melting curve genotyping. Mathematical software algorithms will be written for sensitive variant detection and flagging unknown mutant sequences. The utility of the new instrument and algorithms will be demonstrated by homogenously scanning for mutations within critical exons of the p53 gene. PROPOSED COMMERCIAL APPLICATION: We propose developing instrumentation and analysis software that will allow homogenous mutation scanning for the first time. The system will be used for scanning the p53 tumor suppressor gene, which is mutated in almost all cancers at the time of invasive growth. The instrumentation and the assay will be commercially available for continued research on p53 and to provide a clinical test for the prognosis and treatment of cancer. The general method can be applied to other genes, as well.

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R42
  • Administering IC
    GM
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    263396
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    821
  • Ed Inst. Type
  • Funding ICs
    NIGMS:263396\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    IDAHO TECHNOLOGY
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84108
  • Organization District
    UNITED STATES