Homogeneous Mutation Scanning

Information

  • Research Project
  • 7012678
  • ApplicationId
    7012678
  • Core Project Number
    R42GM072419
  • Full Project Number
    5R42GM072419-03
  • Serial Number
    72419
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/1/2004 - 20 years ago
  • Project End Date
    1/31/2007 - 18 years ago
  • Program Officer Name
    SWAIN, AMY L
  • Budget Start Date
    2/1/2006 - 19 years ago
  • Budget End Date
    1/31/2007 - 18 years ago
  • Fiscal Year
    2006
  • Support Year
    3
  • Suffix
  • Award Notice Date
    1/19/2006 - 19 years ago
Organizations

Homogeneous Mutation Scanning

DESCRIPTION (provided by applicant): Our objective is to provide a homogeneous, closed-tube system for DNA mutation scanning on a high-throughput platform. For many complex genetic diseases, it is very difficult and expensive to screen for all possible mutations that may cause the disease. We propose a relatively simple solution. Certain dyes are compatible with PCR and can detect sequence alterations present in one copy of DNA by simple melting analysis after amplification. The dye is added before PCR, and optionally followed in real-time during amplification. Heterozygotes are easily identified after a 5 min. high-resolution melting curve after PCR. Specific aims for Phase I of this Fast Track proposal include: 1. Identify and/or synthesize scanning dyes that can be used with standard fluorescein optics. 2. Demonstrate that heterozyotes can be identified by high-resolution melting on a 384-well platform. 3. Achieve 90% sensitivity and specificity for single base change heterozygote detection in PCR products up to 300 bps in length. Our currently manufactured 384-well, low-resolution genotyping instrument will be modified for high-resolution scanning. A robust DNA scanning dye for use with standard fluorescein optics will be identified and/or synthesized for this instrument and potentially others. A comprehensive screen of single base mismatches in engineered plasmids will be used to establish the sensitivity and specificity of the system, and provide the criteria for Phase II funding. Advantages of high-resolution melting analysis for mutation scanning include speed (< 5 min), homogeneous design (no need for automation), closed-tube analysis (no amplicon contamination risk), and sample disposition (immediately available for sequencing if necessary).

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R42
  • Administering IC
    GM
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    375000
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    859
  • Ed Inst. Type
  • Funding ICs
    NIGMS:375000\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    IDAHO TECHNOLOGY
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84108
  • Organization District