HT Label-Free Screening and Kinetic Analysis of Small Molecules and Biologics

Information

  • Research Project
  • 8648775
  • ApplicationId
    8648775
  • Core Project Number
    R44GM109738
  • Full Project Number
    1R44GM109738-01
  • Serial Number
    109738
  • FOA Number
    PA-13-088
  • Sub Project Id
  • Project Start Date
    5/1/2014 - 10 years ago
  • Project End Date
    8/31/2015 - 9 years ago
  • Program Officer Name
    EDMONDS, CHARLES G.
  • Budget Start Date
    5/1/2014 - 10 years ago
  • Budget End Date
    8/31/2015 - 9 years ago
  • Fiscal Year
    2014
  • Support Year
    01
  • Suffix
  • Award Notice Date
    4/4/2014 - 10 years ago

HT Label-Free Screening and Kinetic Analysis of Small Molecules and Biologics

DESCRIPTION (provided by applicant): Real-time label-free technologies such as surface plasmon resonance biosensors provide high-resolution information about the kinetics, affinity, stoichiometry, activity, and specificity, of two (or more) binding partners. While the application f biosensors is well established, current instrumentation has limited sampling throughput. Screens of even a fairly small chemical library (e.g., 3000-5000 compounds) require days to weeks to complete using traditional label-free instruments. Because of the quality of the data generated by SPR, drug discovery scientists are clamoring to use enhanced biosensors as a screening tool for small molecule applications; however, lack of throughput hinders their ability to move in this direction. We propose to develop a biosensor platform that has increased throughput yet maintains the data quality and ease of use to which researchers are accustomed. We will couple our novel Continuous Flow Microspotter (CFM) with an enhanced-sensitivity SPR biosensor from BiOptix to enable label-free screening and kinetic analsyis of small molecules and biologics. In high-throughput screening mode our 96 channel integrated CFM/E-biosensor platform will be capable of collecting data for >30,000 samples in less than 24 hours - a sampling rate 24x faster than fastest small-molecule capable label-free biosensor, the Biacore 4000.

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R44
  • Administering IC
    GM
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    329750
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    859
  • Ed Inst. Type
  • Funding ICs
    NIGMS:329750\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    WASATCH MICROFLUIDICS
  • Organization Department
  • Organization DUNS
    171205177
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    841234436
  • Organization District
    UNITED STATES