Improved Scatter Reduction Grids for Mammography

Information

  • Research Project
  • 6549314
  • ApplicationId
    6549314
  • Core Project Number
    R43EB000370
  • Full Project Number
    1R43EB000370-01
  • Serial Number
    370
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/1/2002 - 22 years ago
  • Project End Date
    1/31/2003 - 22 years ago
  • Program Officer Name
    TORRES-ANJEL, MANUEL J.
  • Budget Start Date
    8/1/2002 - 22 years ago
  • Budget End Date
    1/31/2003 - 22 years ago
  • Fiscal Year
    2002
  • Support Year
    1
  • Suffix
  • Award Notice Date
    6/28/2002 - 22 years ago
Organizations

Improved Scatter Reduction Grids for Mammography

DESCRIPTION (provided by applicant):Breast cancer is diagnosed in over 180,000 American women each year, leading to over 40,000 deaths annually. Screening mammography is currently the best diagnostic tool for breast disease. Mikro Systems, Inc. proposes to develop an improved scatter reduction grid for in mammography. Scattered x-ray radiation reduces contrast in all radiographic images. High contrast is especially important in mammography to allow early detection of micro calcifications or unusual masses that may suggest the presence of a cancer. MSI has developed an innovative process for producing mammography grids with better performance than current grids, at a more affordable price. In Phase I, MSI will demonstrate the technical feasibility of producing an improved high-resolution scatter reduction grid. Sample sections of mammography grids will be produced having cell size, septal walls, grid ratio, and density suitable for mammographic imaging. In Phase II, the technique will be scaled up to produce full-size mammography grids and preliminary clinical testing will be conducted. PROPOSED COMMERCIAL APPLICATION: This technology will improve mammagraphic imaging quality and will allow cost effective manufacturing of advanced scatter reduction grids. Additional commercial applications of this technology include improved grids, collimators and detector arrays for computed tomography (CT), nuclear medicine, and general radiography.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R43
  • Administering IC
    EB
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    86660
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:86660\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    MIKRO SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    CHARLOTTESVILLE
  • Organization State
    VA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    229015713
  • Organization District
    UNITED STATES