Improved Spatial Resolution in Magnetoencephalography with an Optically Pumped Magnetometer Array

Information

  • Research Project
  • 9552418
  • ApplicationId
    9552418
  • Core Project Number
    R56EB013302
  • Full Project Number
    2R56EB013302-05
  • Serial Number
    013302
  • FOA Number
    PA-16-160
  • Sub Project Id
  • Project Start Date
    6/1/2012 - 12 years ago
  • Project End Date
    9/29/2018 - 6 years ago
  • Program Officer Name
    WOLFSON, MICHAEL
  • Budget Start Date
    9/30/2017 - 7 years ago
  • Budget End Date
    9/29/2018 - 6 years ago
  • Fiscal Year
    2017
  • Support Year
    05
  • Suffix
  • Award Notice Date
    9/27/2017 - 7 years ago

Improved Spatial Resolution in Magnetoencephalography with an Optically Pumped Magnetometer Array

Project Summary/Abstract The fixed helmet design of commercially available magnetoencephalography (MEG) systems utilizing superconducting quantum interference device (SQUID) magnetometers is designed to fit the 95th percentile of head size and therefore gives suboptimal measurements of the MEG signals for most subjects, especially children. A small head size will result in a gap between the helmet and head of several centimeters, and since the MEG signal amplitude decays as 1/r3, where r is the distance from the neuronal source, this large gap can result in signal attenuation by a factor of ~10. Therefore, placing the sensors on to the head will lead to increases in signal amplitude. Additionally, if sensors are placed on or near the scalp, high spatial frequency variations in the magnetic field will be detectable. Combining these factors, substantially improved spatial resolution in localizing neuronal sources will be enabled. Recent developments in sensor design now makes optically pumped magnetometers (OPMs) ideal for application to the field of MEG, and since they operate above room temperature and can be constructed as individual sensor modules, the sensor layout can be flexible. The long-term goal of this research is to develop a full-head MEG system based on OPMs that can conform to any head size to give the largest possible signal while at a reduced cost compared to cryogenic MEG. The objective of this proposal is to develop a 72-channel OPM MEG system giving partial head coverage to demonstrate improved spatial resolution in the measurement of nearby neuronal sources within the human brain. The system will be rapidly reconfigurable to concentrate the array coverage on an area of interest. Our central hypothesis is that the close proximity of the OPM array will allow a new level of spatial resolution for MEG. In Specific Aim 1, our current OPM-based MEG array with 20 channels will be expanded to a reconfigurable 72-channel system. The reconfigurable array will accommodate varying head sizes, particularly that of small adults and children, and the number of sensors will allow the array to be concentrated over two sections of the brain simultaneously. In Specific Aim 2, analysis techniques specific to the reconfigurable array will be developed. When the array is repositioned for each new subject, real-time array calibration is required for accurate magnetic source localization and external noise suppression. In addition, data simulation will optimize the positioning of the array and reveal the possible improvements in source localization due to access to signals of higher spatial complexity. In Specific Aim 3, the source localization precision between our OPM MEG array and a commercial SQUID-based MEG array will be compared. Tasks involving auditory and visual stimulation will allow us to study spatial variation of brain activity due to changing stimulus parameters. With the expected improvements in signal size and spatial resolution, higher fidelity MEG measurements for people of all head sizes ranging from premature infants to the largest adults are enabled, with broad ranging applications in neuroscience and in understanding and treating brain dysfunction.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R56
  • Administering IC
    EB
  • Application Type
    2
  • Direct Cost Amount
    421372
  • Indirect Cost Amount
    278447
  • Total Cost
    699819
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:699819\
  • Funding Mechanism
    Non-SBIR/STTR RPGs
  • Study Section
    BMIT
  • Study Section Name
    Biomedical Imaging Technology Study Section
  • Organization Name
    SANDIA CORP-SANDIA NATIONAL LABORATORIES
  • Organization Department
  • Organization DUNS
    007113228
  • Organization City
    ALBUQUERQUE
  • Organization State
    NM
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    871233453
  • Organization District
    UNITED STATES