Improved Spatial Resolution in Magnetoencephalography with an Optically Pumped Magnetometer Array

Information

  • Research Project
  • 9789869
  • ApplicationId
    9789869
  • Core Project Number
    R01EB013302
  • Full Project Number
    5R01EB013302-06
  • Serial Number
    013302
  • FOA Number
    PA-16-160
  • Sub Project Id
  • Project Start Date
    6/1/2012 - 14 years ago
  • Project End Date
    7/31/2020 - 6 years ago
  • Program Officer Name
    WANG, SHUMIN
  • Budget Start Date
    8/1/2019 - 7 years ago
  • Budget End Date
    7/31/2020 - 6 years ago
  • Fiscal Year
    2019
  • Support Year
    06
  • Suffix
  • Award Notice Date
    8/27/2019 - 7 years ago

Improved Spatial Resolution in Magnetoencephalography with an Optically Pumped Magnetometer Array

PROJECT SUMMARY/ABSTRACT The goal of this project is to optimize a novel strategy for magnetoencephalography (MEG) neuroimaging to substantially improve resolution and reduce cost. MEG is a non-invasive functional neuroimaging method to map brain activity that is useful for both research, e.g. functional brain mapping and clinical applications, e.g. presurgical epilepsy mapping. Commercial MEG systems using superconducting quantum interference device (SQUID) magnetic sensors use fixed helmets with sensor arrays that are designed for a broad range of head sizes. They give suboptimal measurements for most people with smaller heads and especially for children. Because MEG signal amplitude decays as a function of the distance from the neuronal source, a spatial gap of several cm between helmet and head can attenuate the signal by tenfold. Moreover, placing sensors on or near the scalp would enable detection of high spatial frequency variations in the magnetic field, which would further improve spatial resolution in localizing neuronal sources. This project focuses on the use of optically pumped magnetometers (OPMs) to improve MEG localization accuracy. OPMs will be constructed as individual sensor modules that enable flexible sensor layout. The long- term objective is to develop a full-head MEG system based on OPMs that can conform to any head size to give the largest possible signal. This could improve spatial resolution to 1 mm, at a cost that is lower than cryogenic MEG. The objective of this project is to develop a 72-channel OPM MEG system that gives partial head coverage, and to demonstrate improved spatial resolution in measuring neighboring neuronal sources in the human brain. The system will be readily reconfigurable to focus the sensor array on an area of interest. The central hypothesis is that an OPM array with sensors that are close to the head, and close to each other, will substantially increase MEG resolution to a level approaching 1 mm. Aim 1 is to expand the current OPM array from 20 to 72 channels and to make the array easy to reconfigure. This novel array will accommodate all head sizes, particularly those of small adults and children. The larger number of sensors will allow the array to be concentrated over two sections of the brain simultaneously. Aim 2 is to develop analysis techniques specific to the reconfigurable array. When the array is repositioned for each new subject, real-time array calibration is required for accurate magnetic source localization and external noise suppression. In addition, source localization will be improved based on simulation models that will optimize the array positioning and improve models of neuronal sources. Aim 3 is to compare source localization precision between the novel OPM MEG array and a commercial SQUID-based MEG array. The arrays will be tested with tasks involving auditory and visual stimulation, to study spatial variation of brain activity due to changing stimulus parameters. Improved signal size and spatial resolution should substantially improve MEG fidelity for people of all head sizes, including premature infants, with broad applications in understanding and treating brain dysfunction.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R01
  • Administering IC
    EB
  • Application Type
    5
  • Direct Cost Amount
    217619
  • Indirect Cost Amount
    102381
  • Total Cost
    320000
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIGMS:320000\
  • Funding Mechanism
    Non-SBIR/STTR RPGs
  • Study Section
    BMIT
  • Study Section Name
    Biomedical Imaging Technology Study Section
  • Organization Name
    SANDIA CORP-SANDIA NATIONAL LABORATORIES
  • Organization Department
  • Organization DUNS
    007113228
  • Organization City
    ALBUQUERQUE
  • Organization State
    NM
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    871233453
  • Organization District