Innovative Image-Guided Device for Beating Heart Mitral Valve Repair

Information

  • Research Project
  • 9048088
  • ApplicationId
    9048088
  • Core Project Number
    R44HL131101
  • Full Project Number
    1R44HL131101-01
  • Serial Number
    131101
  • FOA Number
    PAR-14-088
  • Sub Project Id
  • Project Start Date
    9/19/2016 - 9 years ago
  • Project End Date
    2/28/2018 - 7 years ago
  • Program Officer Name
    EVANS, FRANK
  • Budget Start Date
    9/19/2016 - 9 years ago
  • Budget End Date
    8/31/2017 - 8 years ago
  • Fiscal Year
    2016
  • Support Year
    01
  • Suffix
  • Award Notice Date
    9/17/2016 - 9 years ago
Organizations

Innovative Image-Guided Device for Beating Heart Mitral Valve Repair

? DESCRIPTION (provided by applicant): Mitral valve disease is the most prevalent heart valve dysfunction in the U.S., affecting approximately 0.7% of the total population and 3.5% of the population over age 75. With the aging population, the occurrence of severe mitral regurgitation (MR) in the U.S. and Europe is projected to exceed 5M by 2020 and will present an increasing economic burden. The Problem: MR causes a volume overload on the left ventricle which in turn progresses to ventricular dilation, decreased ejection performance, pulmonary hypertension, symptomatic congestive heart failure, atrial fibrillation, right ventricular dysfunction and death. While conventional mitral valve surgery is safe and effective, it remains very invasive and morbid and is significantly underutilized. The Solution: Harpoon Medical has developed technology for minimally invasive, image-guided, beating-heart mitral valve repair, performed via a keyhole incision between the ribs. The innovative device allows an operator to eliminate MR by securing artificial chordae tendineae (neochords) to a prolapsed mitral valve leaflet with a bulky knot anchor and resuspending the leaflet in its normal position. The Harpoon device eliminates the need crack the chest, put the patient on a heart-lung machine and stop the heart. This will transform conventional mitral valve surgery from a complex 3-6 hour operation to a sixty minute procedure and allow patients to return to normal daily activities within a week. Preliminary Data: An ongoing early feasibility study has confirmed that the Harpoon device successfully reduced severe MR to trace in two patients suffering from degenerative mitral valve disease. Specific Aims: This project entails the development work and preclinical testing necessary to create an automated delivery system for human trials in the U.S and accelerate the commercialization of Harpoon's minimally invasive, beating heart mitral valve repair device. In Specific Aim 1 we will develop an automated delivery system with a single button actuator and validate it at the bench and in acute pig studies. In Specific Aim 2 we will develop a method for titrating the length of multiple neochords under echocardiographic guidance and securing them to the epicardial surface of the heart. The automated delivery system developed in Aim 1 and the method for titrating the length of the neochords developed in Aim 2 will be evaluated as part of a clinical study in dogs with degenerative mitral valve disease in Specific Aim 3 to validate the safety, performance and efficacy of the device in a naturally occurring disease model. Expected Outcomes: At the end of this Direct to Phase II SBIR Grant, Harpoon will have a minimally invasive, beating heart mitral valve repair device that has been validated in acute and chronic animal studies and is ready for clinical testing in the U.S. to support FDA approval.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    830130
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:830130\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    HARPOON MEDICAL, INC.
  • Organization Department
  • Organization DUNS
    079188333
  • Organization City
    BALTIMORE
  • Organization State
    MD
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    212018603
  • Organization District
    UNITED STATES