Lab-on-a-chip for multiplexed newborn screening of lysosomal storage disorders

Information

  • Research Project
  • 7747009
  • ApplicationId
    7747009
  • Core Project Number
    R44HD057713
  • Full Project Number
    2R44HD057713-02
  • Serial Number
    57713
  • FOA Number
    PA-08-050
  • Sub Project Id
  • Project Start Date
    9/30/2007 - 16 years ago
  • Project End Date
    8/31/2011 - 12 years ago
  • Program Officer Name
    URV, TIINA K
  • Budget Start Date
    9/5/2009 - 14 years ago
  • Budget End Date
    8/31/2010 - 13 years ago
  • Fiscal Year
    2009
  • Support Year
    2
  • Suffix
  • Award Notice Date
    9/2/2009 - 14 years ago

Lab-on-a-chip for multiplexed newborn screening of lysosomal storage disorders

DESCRIPTION (provided by applicant): Newborn screening is currently performed by collecting dried bloodspots from infants and then sending them to a lab for analysis. Lysosomal storage diseases alone number greater than 40 and there is an increasing necessity to screen for a number of disease conditions for which therapies are becoming available. Tandem mass spectrometry is an excellent multiplex detection technology widely utilized in newborn screening, but when applied to enzyme assays it is very expensive, time consuming, labor intensive, and more importantly the multiplexing power of mass spectrometry is not leveraged because each assay has to be performed individually. There is a need for an inexpensive, rapid, automated, and scalable technology for performing newborn screening assays that a mass spectrometer is not well-suited to perform. A digital microfluidic system for performing enzymatic assays in newborn screening will enable walkaway automation and multiplex several assays very inexpensively. Based on Advanced Liquid Logic's successful demonstration of digital microfluidic manipulation of nanoliter-sized droplets of enzymatic reagents and sample for dispensing from on-chip reservoirs, high speed transport, mixing, splitting and dilution, and absorbance, fluorescence, and luminescence detection of the assays, a disposable lab-on-a- chip will be developed. In phase I, we have successfully demonstrated a multiplex fluorescence enzymatic assay on a digital microfluidic cartridge to setup screening for Pompe, Fabry, and Hurler disorders on dried blood spot samples. Phase II work will focus on increasing the throughput of the cartridge to screen for 6 lysosomal storage disorders for which therapies exist including Pompe, Fabry, Hurler, Hunter, Gaucher, and Maroteaux-Lamy, on 96 dried blood spot samples yielding a total of 576 enzymatic assays on a single cartridge. Also, a pilot screening study will be performed in collaboration with Duke University and North Carolina State Lab of Public Health, which would involve screening about 10,000 dried blood spots on the digital microfluidic platform. PUBLIC HEALTH RELEVANCE: Newborn screening is performed on every infant born in the US and there is a growing interest in increasing the number of conditions screened for. In this project, a digital microfluidic platform will be developed to screen for many treatable conditions simultaneously using much lesser volume of blood from an infant. It would be greatly useful in identifying treatable diseases earlier.

IC Name
EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH &HUMAN DEVELOPMENT
  • Activity
    R44
  • Administering IC
    HD
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    740837
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    865
  • Ed Inst. Type
  • Funding ICs
    NICHD:740837\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ADVANCED LIQUID LOGIC
  • Organization Department
  • Organization DUNS
    140695474
  • Organization City
    RESEARCH TRIANGLE PARK
  • Organization State
    NC
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    277094025
  • Organization District
    UNITED STATES