Low Cost Multi-pathogen Laser Diagnostic for HIV and AIDS Co-Infections

Information

  • Research Project
  • 7460723
  • ApplicationId
    7460723
  • Core Project Number
    R44AI068543
  • Full Project Number
    5R44AI068543-03
  • Serial Number
    68543
  • FOA Number
    PA-06-20
  • Sub Project Id
  • Project Start Date
    1/15/2006 - 19 years ago
  • Project End Date
    8/31/2009 - 16 years ago
  • Program Officer Name
    FITZGIBBON, JOSEPH E.
  • Budget Start Date
    7/1/2008 - 17 years ago
  • Budget End Date
    8/31/2009 - 16 years ago
  • Fiscal Year
    2008
  • Support Year
    3
  • Suffix
  • Award Notice Date
    6/20/2008 - 17 years ago

Low Cost Multi-pathogen Laser Diagnostic for HIV and AIDS Co-Infections

[unreadable] DESCRIPTION (provided by applicant): Precision Photonics Corporation proposes to develop and demonstrate the key technologies for a laser based multi-pathogen diagnostic system for HIV and common co-infections. The ultimate goal is to provide very low cost, easy to use tests at the point of care to help diagnose HIV and its co-infections in resource limited settings. The technology will use novel diode laser illumination and ultra-sensitive detection techniques with low cost optics and lasers, analogous to a DVD sensor head. By combining sensitive detection with an immunoassay format, reagent consumption is minimized. An array of detection spots and segregated tracers allow multi-analyte detection for multi-pathogen diagnosis. In the proposed project, we will (i) Establish a working, manufacturable reference design of the fluidic assay components and fluorescent reader. The cost/performance goals are to achieve a design that can meet a manufacturing cost of <US$50 (goal of US$20) for the reader, <US$0.5 (goal of $0.25) for the cartridge, and with adequate sensitivity for serological assays, (ii) Develop an assay panel for detection of antibodies to HIV, HCV, HBV, HHV-8, HSV 1 & 2, CMV, and T. gondii, (iii) Test the assay panel at UCSD in a cohort of HIV-1 infected persons, and (iv) Test the assay abroad as time and resources permit. The research performed in this project, if successful, will enable very low cost, easy to use tests at the point of care to help in assessment of disease status of AIDS patients in resource limited settings. The simplicity and low cost of the technology will facilitate the use of anti-retroviral therapy, greatly prolonging the lives of those infected with HIV and reducing the burden of disease in populations where HIV is endemic. [unreadable] [unreadable] [unreadable]

IC Name
NATIONAL INSTITUTE OF ALLERGY AND INFECTIOUS DISEASES
  • Activity
    R44
  • Administering IC
    AI
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    331110
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    855
  • Ed Inst. Type
  • Funding ICs
    NIAID:331110\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    PRECISION PHOTONICS CORPORATION (PPC)
  • Organization Department
  • Organization DUNS
    112617480
  • Organization City
    BOULDER
  • Organization State
    CO
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    80301
  • Organization District
    UNITED STATES