METHOD FOR NEONATAL SCREENING FOR HOMOCYSTINURIA

Information

  • Research Project
  • 2869526
  • ApplicationId
    2869526
  • Core Project Number
    R43DK055951
  • Full Project Number
    1R43DK055951-01
  • Serial Number
    55951
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/1/1999 - 25 years ago
  • Project End Date
    2/29/2000 - 25 years ago
  • Program Officer Name
    MCKEON, CATHERINE T
  • Budget Start Date
    9/1/1999 - 25 years ago
  • Budget End Date
    2/29/2000 - 25 years ago
  • Fiscal Year
    1999
  • Support Year
    1
  • Suffix
  • Award Notice Date
    7/29/1999 - 26 years ago
Organizations

METHOD FOR NEONATAL SCREENING FOR HOMOCYSTINURIA

The ability to detect both L-homocysteine and L-methionine is critical for accurate screening for homocystinuria. This research project, if successful, will result in a selective, quantitative assay for L-homocysteine and L- methionine in biological fluids based on the reaction catalyzed by methionine gamma-lyase. The enzyme which is highly selective for L- methionine and L-homocysteine will be isolated from a strain of Pseudomonas and characterized. By coupling the enzymatic decomposition of L-methionine or L-homocysteine to an NADH-oxidizing dehydrogenase, rapid spectrophotometric read-out will be achieved. Conditions for quantitation of L-methionine and L-homocysteine will be developed, and the upper and lower limits of sensitivity will be determined. Possible interference by components of biological fluids will be assessed. Finally, methionine gamma-lyase will be immobilized and tested to establish the feasibility of a test strip for rapid, routine measurements. The commercial application for this work is immediate as a replacement for the Guthrie microbiological assay in neonatal screening, which is unable to detect L- homocysteine. Improved early diagnosis of homocysteinuria will permit more timely and effective treatment, resulting in lower costs and dramatically improved outcomes for homocystinurics. Further opportunities exist for development of a rapid test strip. PROPOSED COMMERCIAL APPLICATIONS: Neonatal screening assay for homocystinuria; home and doctor's office test strip for measurement of L-methionine and L-homocysteine concentrations in urine or blood.

IC Name
NATIONAL INSTITUTE OF DIABETES AND DIGESTIVE AND KIDNEY DISEASES
  • Activity
    R43
  • Administering IC
    DK
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    847
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
  • Organization Name
    BIOCATALYTICS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    PASADENA
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    91106
  • Organization District
    UNITED STATES