METHOD FOR NEONATAL SCREENING FOR HOMOCYSTINURIA

Information

  • Research Project
  • 6298893
  • ApplicationId
    6298893
  • Core Project Number
    R44DK055951
  • Full Project Number
    2R44DK055951-02
  • Serial Number
    55951
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/1/1999 - 25 years ago
  • Project End Date
    12/31/2002 - 22 years ago
  • Program Officer Name
    HANSON, JAMES W
  • Budget Start Date
    2/1/2001 - 24 years ago
  • Budget End Date
    1/31/2002 - 23 years ago
  • Fiscal Year
    2001
  • Support Year
    2
  • Suffix
  • Award Notice Date
    1/29/2001 - 24 years ago
Organizations

METHOD FOR NEONATAL SCREENING FOR HOMOCYSTINURIA

DESCRIPTION: (Applicant's description) In Phase 1 an enzymatic assay for homocysteine was developed with sensitivity down to concentrations of 10-20 micromolar, well below the range of 50-500 micromolar that is indicative of homocystinuria. The feasibility of a test strip for homocysteine detection was demonstrated using an immobilized form of the enzyme and a colorimetric visualization method, providing results within 20 minutes. In Phase 2, the test strip assay will be perfected for use in the neonatal screening for homocystinuria to replace the flawed Guthrie test, which cannot detect homocysteine. Immobilization of the enzyme will be optimized for loading and activity, and the visualization chemistry will be refined. Stability and shelf life will be evaluated and improved as necessary. Expression of the methionine gamma-lyase gene will be increased to reduce the cost of enzyme. The solution assay will be further developed to make the assay viable for routine blood testing. Enzyme selectivity for homocysteine will be enhanced by directed evolution of existing clones. Sample preparation procedures will be optimized to remove potentially interfering substances in physiological fluids. Sensitivity will be improved 5 to 10 fold using fluorescent substrates, with the goal of precise, reproducible quantitation of homocysteine down to the range of 5-10 micromolar. PROPOSED COMMERCIAL APPLICATION: Neonatal screening assay for homocystinuria; home and doctor's office test strip for measurement of L-methionine and L-homocysteine concentrations in urine or blood.

IC Name
NATIONAL INSTITUTE OF DIABETES AND DIGESTIVE AND KIDNEY DISEASES
  • Activity
    R44
  • Administering IC
    DK
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    390480
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    847
  • Ed Inst. Type
  • Funding ICs
    NIDDK:390480\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    BIOCATALYTICS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    PASADENA
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    91106
  • Organization District
    UNITED STATES