MICROWAVE DEVICE FOR BLOOD WARMING &TEMPERATURE CONTROL

Information

  • Research Project
  • 3508613
  • ApplicationId
    3508613
  • Core Project Number
    R44HL038564
  • Full Project Number
    2R44HL038564-02A1
  • Serial Number
    38564
  • FOA Number
  • Sub Project Id
  • Project Start Date
    6/5/1990 - 34 years ago
  • Project End Date
    5/31/1992 - 32 years ago
  • Program Officer Name
  • Budget Start Date
    6/5/1990 - 34 years ago
  • Budget End Date
    5/31/1991 - 33 years ago
  • Fiscal Year
    1990
  • Support Year
    2
  • Suffix
    A1
  • Award Notice Date
    6/4/1990 - 34 years ago

MICROWAVE DEVICE FOR BLOOD WARMING &TEMPERATURE CONTROL

It is estimated that almost 75,000 persons each year will die of acute respiratory insufficiency caused by lung disease alone. To address this problem, extracorporeal membrane oxygenation (ECMO) is used to provide external pumping and membrane oxygenation to assist the weakened of failing heart. Heat exchangers in the extracorporeal circulation (ECC) path are necessary to prevent water loss associated with evaporative heat loss in long term ECMO. Here, a short path length is particularly desirable to minimize the trauma to blood components coming in contact with foreign substances. Heat exchangers can also be used to solve the problem of hypothermia and its associated coagulopathy occuring with trauma, the leading cause of death in young Americans. A small portable unit used in-line where blood and fluid are given could be utilized as early as the pre-hospital phase of support to prevent hypothermia. A microwave transmitter (heater) system is proposed to address problems associated with long term blood warming for ECMO and short term, rapid warming for trauma. This system would be small, portable and provide for a short ECC path. In addition a radiometric temperature measurement system used to complete a closed loop system can by itself be used in applications demanding fast, non-invasive temperature monitoring of flowing fluids.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    2
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    838
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    SSS
  • Study Section Name
  • Organization Name
    MICROWAVE MEDICAL SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    ACTON
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    01720
  • Organization District
    UNITED STATES