MICROWAVE REMEDIATION OF HAZARDOUS MEDICAL WASTES

Information

  • Research Project
  • 7682081
  • ApplicationId
    7682081
  • Core Project Number
    R44ES013803
  • Full Project Number
    5R44ES013803-03
  • Serial Number
    13803
  • FOA Number
    PA-07-280
  • Sub Project Id
  • Project Start Date
    5/15/2005 - 20 years ago
  • Project End Date
    8/31/2010 - 15 years ago
  • Program Officer Name
    SHAUGHNESSY, DANIEL
  • Budget Start Date
    9/1/2009 - 16 years ago
  • Budget End Date
    8/31/2010 - 15 years ago
  • Fiscal Year
    2009
  • Support Year
    3
  • Suffix
  • Award Notice Date
    9/14/2009 - 16 years ago
Organizations

MICROWAVE REMEDIATION OF HAZARDOUS MEDICAL WASTES

DESCRIPTION (provided by applicant): This project proposes to build and test a 20 L capacity Remediator for medical wastes. Infectious Medical Wastes (IMW), mainly from hospitals, represents a major component of hazardous wastes generated in the U.S.. In fact, more than 4.5 million tons are generated per year. Hospital waste remediation was a $1.5 billion industry in 2003. Incineration remains the predominant disposal method, with continued problems of environmental pollution, severe local opposition, transportation, high costs and the threat of recent (1997) laws shutting down incinerators. This firm recently demonstrated a novel technique for remediation of IMW that involves submersing the IMW in proprietary liquids that are specifically activated by microwaves to generate antimicrobial and antiviral activity in a manner as or more effective than an autoclave. This technique uses unique, microwave-active liquids, proprietary microwave enhancers and simple, ambient-pressure techniques. It yields an extremely inexpensive, rapid, environmentally benign, local, point-of-service methodology for remediation of IMW, usable much as a local-area photocopier or shredder. The Phase 1 work further developed this, demonstrating application to a wide variety of mixed IMW, including metallic parts, bandages, gloves, cotton, etc. and actual hospital wastes. Typically, 400 g of wastes in 650 mL of microwave liquid could be remediated in 7 minutes using a 1.1 KW oven, with final weight/-volume reductions to <15% of original. Detailed analyses of thermal degradation products of the microwave liquid and wastes showed none. A mechanical prototype of a Remediator was built and a fully-microwave-functional prototype was designed and evaluated. AOAC Sporicidal Tests and microwave-vs.-heat-only tests were also done in the prior work. In the proposed Phase 2 work, a fully functional Remediator will be built, tested and refined, to arrive at a design suitable for handing over to a large contract manufacturer. AOAC Sporicidal and quantitative tests and tests with actual hospital wastes will be used to verify performance, along with comparisons with extant benchmark methods. The work is a collaborative effort with a highly specialized microwave design company, one of the world's premier university microwave chemistry groups, the Regional Bio-Defense Lab, and a large hospital. Estimated remediation costs are $900/ton for this firm's technology, vs. $2900/ton for incineration, and more for microwave-steam methods. This firm's technology's estimated capital cost is less than $8 K for a 30 kg/hr throughput, as compared to $18 K for on-site autoclaving and $80 K for microwave-steam. PUBLIC HEALTH RELEVANCE: The technology could, potentially, entirely replace incineration of medical wastes (already beset with public health problems) as well as expensive methods such as in-situ autoclaving and microwave-steaming, yielding an inexpensive, environmentally benign, and local, point-of-service method for medical waste remediation, to great public benefit [1-26]. Independent studies [2-4] show it could initially (within 5 years) capture about 10% to 30% of the more than $2 billion (in 2008) medical waste remediation market, possibly more subsequently. This firm's technology's estimated running costs are 1/3 to 1/6 that of other methods, its capital costs are 1/3 to 1/10 of other methods, and, in contrast to other methods which (with the exception of incineration) leave a large amount of residual waste, it leaves less than 15% of the original volume of waste.

IC Name
NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES
  • Activity
    R44
  • Administering IC
    ES
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    419731
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    113
  • Ed Inst. Type
  • Funding ICs
    NIEHS:419731\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ASHWIN-USHAS CORPORATION, INC.
  • Organization Department
  • Organization DUNS
    807772942
  • Organization City
    HOLMDEL
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    077331138
  • Organization District
    UNITED STATES