Millipede Percutaneous Annuloplasty Ring

Information

  • Research Project
  • 7999546
  • ApplicationId
    7999546
  • Core Project Number
    R43HL102961
  • Full Project Number
    1R43HL102961-01A1
  • Serial Number
    102961
  • FOA Number
    PA-09-080
  • Sub Project Id
  • Project Start Date
    7/20/2010 - 14 years ago
  • Project End Date
    7/31/2011 - 13 years ago
  • Program Officer Name
    MILLER, MARISSA A.
  • Budget Start Date
    7/20/2010 - 14 years ago
  • Budget End Date
    7/31/2011 - 13 years ago
  • Fiscal Year
    2010
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    7/20/2010 - 14 years ago
Organizations

Millipede Percutaneous Annuloplasty Ring

DESCRIPTION (provided by applicant): Heart valve regurgitation is a serious condition related to heart disease. The most common and effective surgical method for treating this disease is with the use of an annuloplasty ring, which reduces the size of a dilated valve annulus to restore normal function. Many patients do not receive this procedure, however, either because they are too sick to undergo open heart surgery, or their condition has not yet progressed to the point at which surgery is justified. To address this large untreated patient population, many efforts have been undertaken to develop technology to repair leaky valves via catheter. Of these, the Millipede concept is the only device which can perform a true ring annuloplasty. This concept uses a ring that can both expand and contract under a radial force and has many small barbed anchors around its perimeter. The ring is mounted on the proximal end of an expandable, cone- shaped delivery tool prior to delivery. The collapsed dilator-ring assembly is advanced toward the annulus and the apex of the cone is pushed through the valve orifice. The cone is then expanded, which simultaneously expands the ring to a known diameter and forces the annulus into a circular shape with the same diameter, resulting in automatic alignment of the ring and the annulus. Once aligned, a simple forward push of the delivery tool drives the barbed anchors into the tissue and secures the ring in place. The dilator tool is then contracted down and removed. In Phase I of this project we will build functional prototypes of the ring and delivery tool and test their performance on the benchtop in pig hearts. In Phase II we will further develop this device and conduct testing necessary to achieve regulatory approval for surgical use. Also in Phase II, we will develop the delivery system needed to implant the device percutaneously. PUBLIC HEALTH RELEVANCE: The goal of this project is to develop a sutureless annuloplasty ring for the treatment of dilated, leaking heart valves. This will lead to an annuloplasty ring that can be implanted without surgery, which will benefit a significant number of patients who have valve disease but are not candidates for surgery.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    147611
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:147611\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    MC3, INC.
  • Organization Department
  • Organization DUNS
    806687406
  • Organization City
    ANN ARBOR
  • Organization State
    MI
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    481038802
  • Organization District
    UNITED STATES