Miniature, rapid, and 3-dimensional OCT scanner for dental imaging

Information

  • Research Project
  • 7748057
  • ApplicationId
    7748057
  • Core Project Number
    R43DE019602
  • Full Project Number
    1R43DE019602-01A1
  • Serial Number
    19602
  • FOA Number
    PA-08-050
  • Sub Project Id
  • Project Start Date
    8/1/2009 - 15 years ago
  • Project End Date
    7/31/2010 - 14 years ago
  • Program Officer Name
    DRUMMOND, JAMES
  • Budget Start Date
    8/1/2009 - 15 years ago
  • Budget End Date
    7/31/2010 - 14 years ago
  • Fiscal Year
    2009
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    7/24/2009 - 15 years ago
Organizations

Miniature, rapid, and 3-dimensional OCT scanner for dental imaging

DESCRIPTION (provided by applicant): Agiltron proposes an innovative dental OCT (optical coherence tomography) miniature probe with a unique and high speed 2D MEMS scanner. This will enable the miniaturization of the two dimensional probe, so that dentist need only hold a probe in a fixed position against a tooth and obtain a complete three dimensional scan of the structure in less than one second. The small size of the MEMS mirror allows the device to be packaged in a compact form factor compatible with the constrained geometry of the mouth. Agiltron will also incorporate a novel fiber-tip lens to focus the beam, which will enable further miniaturization and cost reduction. The probe will be comparable in size to other dental instruments such as the UV light guide used for curing resins. Phase I will undertake the design and fabrication of a prototype OCT probe with integrated MEMS scanning mirror and a miniature fiber focusing lens, and demonstrate the feasibility of the technology by scanning tooth samples. Phase II will fabricate a complete probe and demonstrate the utility of the technology in laboratory and clinical tests. The mainstay of diagnostic imaging in dental practices today is dental radiography (x-ray), which was first used in dentistry in 1885. This technology has severe limitations in providing the detailed information needed for early detection of decay and in imaging the occlusal, or biting surfaces of the rear or molar teeth, where up to 80% of all tooth decay originates. It has been previously shown that OCT provides an improvement over x-ray imaging, particularly in imaging the biting surfaces of teeth and regions adjacent to prior restorative work and in detecting very early stage decay. It is particularly promising for children because of the potential speed of the imaging and because of the absence of ionizing radiation. However, currently available probes for dental OCT do not have integrated lateral scanning. One dimension of lateral scanning, to allow the acquisition of discrete tomography slices, can be provided by an external scanner but it is bulky. The integration of a miniature 2 dimensional MEMS scanner into the probe will preserve its compact nature and will enable the acquisition of true 3D scans of the teeth. PUBLIC HEALTH RELEVANCE: Optical Coherence Tomography promises to advance on state-of-the art dental imaging, primarily X-rays, by creating accurate 3-dimensional scans of structures within the teeth and gums. It offers enhanced ability to image very early decay, the biting surfaces of teeth, regions adjacent to existing restorations, and soft tissue such as gums, and is particularly promising for children because of the potential speed of the imaging and because of the absence of ionizing radiation. This will allow earlier treatment of dental disease which will result in improved oral health and potentially in reduced costs.

IC Name
NATIONAL INSTITUTE OF DENTAL &CRANIOFACIAL RESEARCH
  • Activity
    R43
  • Administering IC
    DE
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    99982
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    121
  • Ed Inst. Type
  • Funding ICs
    NIDCR:99982\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    AGILTRON, INC.
  • Organization Department
  • Organization DUNS
    004841644
  • Organization City
    WOBURN
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    018011003
  • Organization District
    UNITED STATES