NASO-GASTRIC FEEDING TUBE PLACEMENT VERIFICATION SYSTEM

Information

  • Research Project
  • 2286249
  • ApplicationId
    2286249
  • Core Project Number
    R43RR010676
  • Full Project Number
    1R43RR010676-01
  • Serial Number
    10676
  • FOA Number
  • Sub Project Id
  • Project Start Date
    3/1/1995 - 30 years ago
  • Project End Date
    8/31/1995 - 30 years ago
  • Program Officer Name
  • Budget Start Date
    3/1/1995 - 30 years ago
  • Budget End Date
    8/31/1995 - 30 years ago
  • Fiscal Year
    1995
  • Support Year
    1
  • Suffix
  • Award Notice Date
    2/24/1995 - 30 years ago
Organizations

NASO-GASTRIC FEEDING TUBE PLACEMENT VERIFICATION SYSTEM

Naso-gastric (NG) feeding tubes are used to deliver nutrition to patients who cannot eat for themselves in nursing homes, hospitals, and home care settings. Improper placement into the lungs or trachea of NG tubes by caregivers can result in complications, including pneumonia and death. Currently, the only certain method of proper NG tube placement is radiographic - an X-ray film is taken of the abdomen to verify the location of the tip of the NG tube. However, X-rays deliver a radiation dose, are time consuming, and are relatively expensive. a hand-held, non-radiographic, NG tube position verification system would improve patient care in many situation by reducing both risks and cost. During phase I, a prototype non-radiographic, NG tube verification system will be developed. It will be based around a technology licensed from the University of Washington, Seattle. The specific Phase I goal is to establish the feasibility and costs of a system using this technology. During Phase II, the prototype will be refined and developed into a hand- held unit. It will be used in preliminary clinical trials to establish the system's accuracy relative to X-ray verification, and to begin fulfilling FDA licensing criteria. PROPOSED COMMERCIAL APPLICATION: It is estimated that about 7 million NG feeding tubes are placed into patients per year in the US, and that at least 10% of these are inserted with X-ray confirmation. X-ray confirmation costs to the patient range from $80 to $100 - giving an approximate health care cost of over $60 million. A large percentage of this cost (and associated physician time) would be eliminated by the proposed non-radiographic system. In addition, this system would allow NG tubes to be confidently placed in patients where there is no ready access to X-ray equipment, for example in nursing homes or in the patient's own home.

IC Name
NATIONAL CENTER FOR RESEARCH RESOURCES
  • Activity
    R43
  • Administering IC
    RR
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    371
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG7
  • Study Section Name
  • Organization Name
    LUCENT MEDICAL SYSTEMS, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    KIRKLAND
  • Organization State
    WA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    98033
  • Organization District
    UNITED STATES