NEW CORNEAL TOPOGRAPHY ALGORITHM AND ITS APPLICATIONS

Information

  • Research Project
  • 2711153
  • ApplicationId
    2711153
  • Core Project Number
    R44EY011211
  • Full Project Number
    5R44EY011211-03
  • Serial Number
    11211
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/30/1995 - 29 years ago
  • Project End Date
    8/31/2001 - 23 years ago
  • Program Officer Name
  • Budget Start Date
    9/1/1998 - 26 years ago
  • Budget End Date
    8/31/2001 - 23 years ago
  • Fiscal Year
    1998
  • Support Year
    3
  • Suffix
  • Award Notice Date
    9/17/1998 - 26 years ago
Organizations

NEW CORNEAL TOPOGRAPHY ALGORITHM AND ITS APPLICATIONS

DESCRIPTION: Recently, computer based videokeratography (VK) has become important for measuring corneal shape before and after refractive surgery and in diagnosing keratoconus. Regrettably, present algorithms are flawed because they assume light rays that form the VK image lie in the meridional plane before and after reflection from the cornea. For both keratoconus and refractive surgery this assumption can produce substantial errors. The investigators have begun development of a new algorithm that eliminates such errors. There are a number of topic on which further research is needed before the algorithm is viable. The investigators will also develop software for splicing and averaging multiple shots to extend coverage to the whole cornea and to reduce noise. Also, they will develop two end-user applications: 1) Software for fitting hard and soft toric contact lens (for correction of astigmatism) that will take into account corneal topography to achieve improved lens centration and orientation. They expect to develop the first successful contact lens fitting software, enabling VK to become a standard instrument for contact lens fitting. Presently several thousand videokeratoscope instruments are being used for refractive surgery and for diagnosing keratoconus. The number of instruments will expand rapidly if improved algorithms for measuring corneal shape and improved applications software become available. As one example, the market for a clinically superior contact lens fitting package in very large (especially true for the many countries with few trained contact lens specialists). The investigators expect that software will be the first to win clinical approval.

IC Name
NATIONAL EYE INSTITUTE
  • Activity
    R44
  • Administering IC
    EY
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    867
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
  • Organization Name
    NEUROMETRICS INSTITUTE
  • Organization Department
  • Organization DUNS
  • Organization City
    OAKLAND
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    94619
  • Organization District
    UNITED STATES