NON-INVASIVE BRESLOW THICKNESS MEASUREMENT FOR MELANOMAS

Information

  • Research Project
  • 6294820
  • ApplicationId
    6294820
  • Core Project Number
    R44CA090029
  • Full Project Number
    1R44CA090029-01
  • Serial Number
    90029
  • FOA Number
  • Sub Project Id
  • Project Start Date
    4/19/2001 - 23 years ago
  • Project End Date
    7/31/2001 - 23 years ago
  • Program Officer Name
    BAKER, HOUSTON
  • Budget Start Date
    4/19/2001 - 23 years ago
  • Budget End Date
    7/31/2001 - 23 years ago
  • Fiscal Year
    2001
  • Support Year
    1
  • Suffix
  • Award Notice Date
    4/18/2001 - 23 years ago
Organizations

NON-INVASIVE BRESLOW THICKNESS MEASUREMENT FOR MELANOMAS

DESCRIPTION (Verbatim from the Applicant's Abstract): The aim of the proposed effort is to demonstrate the feasibility of an innovative method for in vivo preoperative evaluation of malignant cutaneous melanoma. This method will analyze images of melanomas in the visible and near infrared acquired with a multispectal digital dermoscope, MelaFind(tm), developed by Electro-Optical Sciences, Inc., for automatic detection of cutaneous melanoma. The method will meet the following goals: (1 ) reliable in vivo differentiation of invasive from in situ melanomas; (2) in vivo estimation of Breslow thickness for invasive melanomas with an accuracy not worse than that of the standard histological determination. Breslow thickness is one of the most important predictors of the prognosis of cutaneous melanoma. It is also used to decide on surgical management as well as work-up and follow-up strategies for melanoma patients. Thus the proposed method has the potential to improve the care of melanoma patients and to reduce the cost of health care by reducing the number of re-excisions of the tumor. The feasibility of the method will be demonstrated in Phase I. In Phase II, a software package (MelaMeter) for noninvasive Breslow thickness measurement, will be developed and tested with MelaFind (tm). PROPOSED COMMERCIAL APPLICATION: The proposed product is a practical hand-held and portable instrument that will perform two functions: 1) differentiation between invasive and in situ melanomas and 2) estimation of Breslow thickness. This product has the potential of benefit 100,000 new melanoma patients each year in the U. S.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R44
  • Administering IC
    CA
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    88786
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
    NCI:88786\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ELECTRO-OPTICAL SCIENCES, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    IRVINGTON
  • Organization State
    NY
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    10533
  • Organization District
    UNITED STATES