Nonthrombogenic, Antiseptic Nitric Oxide Releasing Catheters

Information

  • Research Project
  • 8902256
  • ApplicationId
    8902256
  • Core Project Number
    R44HL114148
  • Full Project Number
    5R44HL114148-03
  • Serial Number
    114148
  • FOA Number
    PA-13-234
  • Sub Project Id
  • Project Start Date
    8/1/2012 - 12 years ago
  • Project End Date
    4/30/2017 - 7 years ago
  • Program Officer Name
    WARREN, RONALD Q
  • Budget Start Date
    5/1/2016 - 8 years ago
  • Budget End Date
    4/30/2017 - 7 years ago
  • Fiscal Year
    2016
  • Support Year
    03
  • Suffix
  • Award Notice Date
    5/23/2016 - 8 years ago
Organizations

Nonthrombogenic, Antiseptic Nitric Oxide Releasing Catheters

DESCRIPTION (provided by applicant): This proposal involves the incorporation of a proprietary nitric oxide (NO) releasing polymer material (NORL) into a venous catheter to reduce infection and clotting. Low levels of NO released by the normal endothelium inhibit platelet adhesion and activation, thus preventing thrombus formation. Further, it has been shown that NO at low doses exhibits significant bactericidal activity. Hence, the preparation of catheters that secrete NO will solve two longstanding problems in the care of critically ill patients. In Phase 1 of this SBIR, we: 1) developed a unique NO secreting polymer material that can release NO above physiological levels for up to 21 days, with minimal leaching of byproducts; 2) tested the materials for cytotoxicity and hemolysis, and conducted testing in a sheep model to evaluate thrombogenicity and bacterial adherence. We addressed handling and packaging requirements to maintain efficacy of the materials. Based on the cost of materials and the specialized handling requirements, we identified a product that would benefit from the prolonged protection offered by the material, and that has a high enough sale price to tolerate the increased handling expenses. This Phase II application is targeted at building out the manufacturing process found to be most effective for incorporating NORL in the catheter, performing extensive preclinical assessments, and evaluating the coating in vivo for anti-microbial and anti-platelet properties. The initial target product for NORL will be a dual lumen catheter (DLC) suitable for adult extracorporeal membrane oxygenation (ECMO). Specifically, we will construct a device for automated and controlled fabrication of the NORL catheter, and conduct design verification of the NORL loaded catheter. We will also work with our collaborators, at the University of Michigan, to perform extensive in vivo evaluations of the new NO release catheter. At the conclusion of Phase II, we will be prepared to transfer the developed process and equipment to a contract manufacturer. This approach is a significant advance in improving the biocompatibility and anti-microbial features of intravascular catheters since it utilizes chemistry that exactly mimics endogenous NO release function in our bodies, including from endothelial cells to inhibit platelet adhesion/activation, and by various immune cells (e.g., macrophages, neutrophils, etc.) to kill bacteria. By decreasing both clotting and infection, this technology will simultaneously increase catheter longevity and decrease patient morbidity and costs.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R44
  • Administering IC
    HL
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    524620
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:524620\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    MC3, INC.
  • Organization Department
  • Organization DUNS
    806687406
  • Organization City
    DEXTER
  • Organization State
    MI
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    481301563
  • Organization District
    UNITED STATES