Novel High Resolution Scintillator for Imaging Bone Microarchitecture in Flat Panel Cone Beam CT

Information

  • Research Project
  • 9555332
  • ApplicationId
    9555332
  • Core Project Number
    R43AR073707
  • Full Project Number
    1R43AR073707-01
  • Serial Number
    073707
  • FOA Number
    PA-17-302
  • Sub Project Id
  • Project Start Date
    6/1/2018 - 6 years ago
  • Project End Date
    5/31/2019 - 5 years ago
  • Program Officer Name
    WANG, XIBIN
  • Budget Start Date
    6/1/2018 - 6 years ago
  • Budget End Date
    5/31/2019 - 5 years ago
  • Fiscal Year
    2018
  • Support Year
    01
  • Suffix
  • Award Notice Date
    5/25/2018 - 6 years ago

Novel High Resolution Scintillator for Imaging Bone Microarchitecture in Flat Panel Cone Beam CT

Abstract Pathological changes in bone microarchitecture are associated with a broad range of musculoskeletal (MSK) diseases, including osteoporosis (OP) and osteoarthritis (OA). OP and OA carry significant healthcare burden, with an estimated 10 million US adults suffering from OP and 27 million afflicted by OA. This motivates quantitative assessment of bone microstructure on clinical imaging systems. Quantitative metrics of bone microarchitecture remain, however, underutilized in OP and OA because of limited spatial resolution of current orthopedic imaging modalities. Application of extremity CBCT in quantitative imaging of bone microstructure is likely to have high impact in OA and OP because (a) OA occurs primarily in the extremities, and (b) in OP, morphological measurements in distal extremities were shown to be indicative of fracture risk, including of hip fractures. Again, the spatial resolution of current extremity CBCT (?0.25 mm) is insufficient to fully resolve the ?0.1 mm trabeculae, limiting the performance in assessment of bone quality. We intend to address this specific issue through the development of a novel sensor that promises to provide the necessary resolution without compromising detector sensitivity. Efficacy of such a detector will be demonstrated through CBCT scanning and comparing results to those obtained using the current state-of-the-art system.

IC Name
NATIONAL INSTITUTE OF ARTHRITIS AND MUSCULOSKELETAL AND SKIN DISEASES
  • Activity
    R43
  • Administering IC
    AR
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    216807
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    846
  • Ed Inst. Type
  • Funding ICs
    NIAMS:216807\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    RADIATION MONITORING DEVICES, INC.
  • Organization Department
  • Organization DUNS
    073804411
  • Organization City
    WATERTOWN
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    024724624
  • Organization District
    UNITED STATES